a. not occur
b. occur
c. may occur and may not occur
d. sometimes occur and sometimes not
b. occur
a. not occur
b. occur
c. may occur and may not occur
d. sometimes occur and sometimes not
a. not occur
a. equal or greater
b. equal or lower
c. lower
d. equal
a. equal or greater
a. increasing the height of the free fluid level
on the supply tank
b. reducing the temperature of the fluid
c. using larger pipe size in the suction side
d. all of these
d. all of these
a. NPSH = Hb-Hv-Z + hf
b. NPSH = Hb-Hb-Z- hf
C. NPSH = Hb + Hv - Z-hf
d. NPSH = Hb + Hv - Z+hf
b. NPSH = Hb-Hb-Z- hf
a. NPSH = (PB - Pv)/w + Z+hf
b. NPSH (PB - Pv)/w + Z-hf
c. NPSH = (PB + Pv)/w + Z-hf
d. NPSH = (PB + Pv)/w +Z+hf
b. NPSH (PB - Pv)/w + Z-hf
a. decrease the available NPSH
b. increase the required NPSH
c. increase the available NPSH
d. none of these
c. increase the available NPSH
a. Varying
b. constant
c. unity
d. increasing
b. constant
a. indirectly proportional
b. directly proportional
c. inversely proportional
d. unity
b. directly proportional
a. there is no effect
b. saturation temperature increases
c. saturation temperature decreases
d. saturation temperature remains the same
b. saturation temperature increases
a. saturation temperature increases
b. saturation temperature decreases
c. saturation temperature remains the same
d. there is no effect
a. saturation temperature increases
a. directly
b. indirectly
c. Inversely
d. inversely and indirectly
a. directly
a. directly
b. indirectly
c. inversely
d. inversely and indirectly
a. directly
a. vacuum
b. atmospheric pressure
c. above atmospheric
d. zero
a. vacuum
a. for a superheated cycle
b. lower for superheated cycle
c. greater for saturated cycle
d. lower for saturated cycle
a. for a superheated cycle
a. Decreases
b. remains the same
c. proportional
d. increases
d. increases
a. decrease in efficiency
b. increases in efficiency
c. efficiency remains the same
d. varies directly
a. decrease in efficiency
a. at wet-bulb temperature
b. above its dew point temperature
c. at critical temperature
d. below its dew point temperature
d. below its dew point temperature
a. 0%
b. 75%
c. 25%
d. 100%
d. 100%
a. Refrigeration
b. air conditioning
c. ducting system
d. air mixing
b. air conditioning
a. Pump
b. compressor
c. expansion valve
d. drier
b. compressor
any space.
a. ventilation
b. evaporation
c. air supply
d. natural convection
a. ventilation
a. expansion coil
b. condenser coil
c. evaporative condenser
d. cooling tower
a. expansion coil
b. Q1 + Q2