3 problems that occur due to large grain structure, porosity or precipitates.
What are the solutions for scattering, attenuation and noisy screen?
What problems could occur with a rough surface? (3)
What are 3 solutions to rough surface problems (mode conversion/refraction, attenuation and widening of IP)? (3)
What are 2 problems that could occur when testing a hot surface?
2. Cannot obtain results
What are 2 solutions to testing on a hot surface?
2. Use a high temp couplant
What problem could occur with testing on a vertical or overhead surface? And the solution?
Problem: Couplant runs down
Solution: use thicker couplant
What 2 problems could occur with testing a specimen with unparalleled surfaces?
2. Loss of back surface reflection
What is a solution to testing a specimen with unparalleled surfaces?
Obtain measurements or blueprint of the part
What are 2 problems you could encounter with testing a long thin specimen?
Mode conversion and attenuation.
When testing a long thin specimen, what are two solution to the mode conversion and attenuation you will encounter?
2. Inspect from both ends
What are 3 problems you may encounter when testing on a small concave/convex surface?
What is a solution to the problems you will encounter when testing small concave/convex surfaces?
Use a cylindrical lens that matches contour of the part.
What are two problems you may encounter when testing thin material?
2. Hard to read indications
What are 3 solutions to the problems you will encounter when inspecting thin material (defects in dead zone and hard to read indications)?
What problem will you encounter when inspecting large surfaces?
Time consuming
How can you speed up inspection when testing a large surface?
Use a larger diameter or paintbrush transducer
What problem will you encounter when testing for a discontinuity at an angle?
Small/no signal from discontinuity
How do you fix the problems that will be involved with finding a discontinuity at an angle?
Use an angle-beam transducer
What problem might you encounter when testing a rough discontinuity? And what is the solution?
Problem: reduced signal due to scatter
Solution: increase gain
What problem might you encounter with a discontinuity in the dead zone?
Can’t detect in
What are 6 solutions when trying to detect a discontinuity in the dead zone?
Increasing the diameter of probe will do what to penetration power?
Increase it
Increasing diameter of probe will do what to the beam spread?
Decrease it