Pd 957
Revised rules and regulations implementing the subdivision and condominium buyer’s protective decree
Site criteria
Location
Physical suitability
Accessibility
Rule 1
Minimum design standards
Planning and designing of subdivision projects shall take into account the following
Planning and designing of subdivision projects shall take into account the following
Open spaces shall conform to the provisions of PD1216 and its implementing rules and shall include the following
Streets
Walks
Parks and playground
A street or road linking the site and serves as the main traffic artery
Major road
A street or road that services pedestrian/vehicular traffic from minor roads leading to major roads
Collector road
A road which main function is to provide direct access to lots and other activity centers
Minor road
Shall have a right-of-way of not less than 6 meters un width with provisions of sufficient space for vehicular turn around in the form of a cul-de-sac,loop, branch or T, with a maximum length of 60 meters inclusive of terminal
Motor courts
Roads which provide for the distribution of traffic among individuals lots and activity centers
Service roads
A 2meter wide walkway which shall be used to break a block and to serve pedestrians and for emergency purposes
Alley
ROW open market
2.5 below - 10 8
2.5 -5 - 12 10 8
5-10 - 12 10 8
10-15 - 12 10 8
15-20 - 15 12 10
Above 30 - 15 12 10
Motor - 6 5
Alley - 2 2
ROW medium cost
2.5 below - 10 - 8
2.5 -5 - 10 8
5-10 - 12 10 8
10-15 - 12 10 8
15-20 - 12 10 8
Above 30 - 15 12 10
Motor - 6 5
Alley - 2 2
Distance between offset intersections should not be less than ____ from corner to corner.
20m
Crowns of the roads shall have a slope of not less than ______, while curbs and gutter shall not be less than ___
1.5%
7-9%
Maximum length of block shall be
400m
Block exceeding _____ shall provide an alley
250m
MWSS
Metropolitan waterworks and sewerage system
LWUA
Local waters utilities administration
Minimum drainage pipes diameter shall be
30cm
Concrete road pavement shall have a minimum thickness of ____ and a minimum compressive strength of ____
150mm
20.7 MPa
Side walk pavement shall have a minimum compressive strength of
17.2 MPa
PD 856
Sanitation code of the Philippines