What kind of APU do we have and describe it?
What kind of APU do we have and describe it?
What controls the APU?
What battery is used for APU Start?
What controls the APU?
Its dedicated dual channel FADEC
What battery is used for APU Start?
BATTs 1 (FADEC & EICAS) and 2 (APU Start Bus)
or
BATTs 1 and DC GPU
What is the fuel source for the APU?
What is the fuel source for the APU?
What fuel pump is used to start the APU?
What fuel pump is used to start the APU?
Will the APU shutdown automatically if speed and
acceleration rate isn’t reached in starting cycle time?
Will the APU shutdown automatically if speed and
acceleration rate isn’t reached in starting cycle time?
Yes
How many different ways can fuel be supplied to the APU?
How many different ways can fuel be supplied to the APU? • DC Fuel Pump (tank 2) • AC Fuel Pump (tank 2) • Tank 2 ejector pump • Tank 1 ejector pump via X-Feed • Tank 1 AC Fuel Pump via X-Feed
When does the APU auto shutdown in flight?
When does the APU auto shutdown in flight?
When does the APU auto shutdown on the ground?
When does the APU auto shutdown on the ground?
What does selecting the OFF position on the APU selector
do?
What does selecting the OFF position on the APU selector
do?
When is electrical and pneumatics available from the APU
after APU start?
When is electrical and pneumatics available from the APU
after APU start?
95% plus 3 seconds
Can APU shutdown be canceled?
Can APU shutdown be canceled?
Yes, moving the APU start switch back to ON before 1 min
cooldown period is over
How can the APU be shutdown immediately?
Yes
How can the APU be shutdown immediately?
Yes
1. APU EMER STOP is pressed
2. BATTs are turned OFF during 1 min cooldown
What will happen if batteries are turned OFF during the 1-minute cool down period?
What will happen if batteries are turned OFF during the 1-minute cool down period?
The APU will shut down immediately
Can the APU be started after a critical fault?
Max start EGT for APU Start?
Max EGT for continuous operation?
Max Rotor Speed of the APU?
Max continuous and transient oil temps for the APU?
Can the APU be started after a critical fault?
No
Max start EGT for APU Start?
1032 ̊ C
Max EGT for continuous operation?
717 ̊ C is start of the Red; amber is permitted 662 ̊ - 717 ̊
Max Rotor Speed of the APU?
108%
Max continuous and transient oil temps for the APU?
155 ̊ C and 163 ̊ C (up to 15 mins)
What are the electrical numbers associated with the APU AC
Generator?
What are the electrical numbers associated with the APU AC
Generator?
115 VAC, 400 Hz, 3-Phase, 40 KVA
Which fuel pump provides fuel supply to APU during engine
start with AC GPU avail, unavail, and after engine start?
AC Avail for start = ACMP2
AC Unavail = DCMP
After Engine #2 Start = primary ejector in right integral tank
Can you restart the APU after receiving a APU Fail EICAS
Message?
Can you restart the APU after receiving a APU Fail EICAS
Message?
No; automatic shutdown has occurred;
APU Bleed Priority
APU Bleed Priority
What 3 things open or are energized when you move APU
Start Knob to ON?
What 3 things open or are energized when you move APU Start Knob to ON? 1. APU FADEC is energized 2. APU EICAS messages are displayed 3. APU Fuel SOV opens
What is closed when the APU Emer. Stop Button is pressed?
What is closed when the APU Emer. Stop Button is pressed?
What powers APU Start Sequence?
What powers APU Start Sequence?
Batt 1 FADEC, Batt 2 APU Start Bus which powers Electronic
Starter Controller –> Brushless Starter Generator (attached to
rotor shaft for APU Start, basically electronic version of Air
Turbine Starter)
What provides the EICAS with APU temp information?
What provides the EICAS with APU temp information?
2 thermocouples located in the exhaust section of the APU that
are dangling in front of outgoing exhaust air