APU
Up to which altitude can the APU be started and operated ?
Maximum certified altitude : 43 100 ft
APU
Can the APU be started if the left CCR is not online ?
NO
The APU controller will delay the start until the required common core applications are available.
Left CCR will take 2-3 minutes to start.
APU
What are the 2 operating modes ofthe APU ?
APU
What is the difference between Attended and Unattended mode ?
In both modes, the APU will auto shutdown under different conditions (fire, overspeed, controller failure, speed droop…).
BUT, in Attended mode,the 3 following conditions will NOT trigger an auto shutdown:
APU
When does the amber caution APU LIMIT appear on the EICAS ?
The APU is in Attended mode, and one of the following faults occurred :
• High EGT
• High oil temperature
• Low oil pressure
(These conditions would trigger an Autoshutdown in Unattended mode.)
APU
Is there a cool down periodafter an APU shutdown (manual or auto) ?
* NO if Auto shutdown or through the APU FIRE handle.
APU
Can the APU be started with NO fuel pumps operating ?
YES
On the ground or in-flight up to 14 000 ft
APU
If AC power is available, which fuelpump will feed the APU?
Left aft fuel pump
APU
If AC power is NOTavailable, which fuel pump will feed the APU ?
Left dedicated DC pump
APU
How many starter/generators does the APU have ?
2
only one used for starts
APU
When starting on battery, how many start attempts are possible ?
2
The APU battery is designed to support 2consecutive startattempts.
(if the second attempt fails, a 5 minutes cooling period must be observed before athird attempt is made)
APU
Is there a cooling period to observe in case of failed battery start ?
YES, after the second failed attempt : 5 minutes
APU
Will the APU ever automatically start ?
YES
In flight, if three or more engine generators are off-line the APU automatically starts, regardless of the APU selector position.
APU
If an automatic APU start was triggered in-flight, can it be shutdown ?
YES
APU
When positioned to OFF, does the APU shutdown immediately ?
NO
There is a 2 minute cool down period during which APU COOLDOWN is displayed in white on the EICAS.
APU
Is the APU overspeed protection ever tested ?
Yes, at every normal shutdown !
After the 2 minute cooldown period is finished, an APU overspeed condition is simulated to trigger a fuel shutoff protection, thus shutting down the APU.
APU
What are theAttended and Unattended modes ?