Q

what is the purpose of the condenser air removal system?

A
  1. Removes air and non-condensable gases from the condenser to achieve initial operational vacuum requirements.
  2. Helps maintain vacuum during normal plant operation
  3. Provides the means for breaking condenser vacuum during plant shutdown
  4. Establish, adjust and remove nitrogen overpressure
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are the mechanical condenser air removal pumps used for?

A

The mechanical air removal pumps are used to establish initial vacuum to approximately 10” Hg within about 30 minutes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What are the steam jet air ejectors used for?

A

SJAE are used to reduce the condenser pressure to the normal operating pressure of 1-2” Hg absolute

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Where are the SJAE?

A

38’ Turbine building west

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What system cools SJAE?

A

Condensate flow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Where is the discharge for the SJAE? Where is the back up dishcarge for the SJAE?

A

Discharge throught the site stack through the GWS

into the turbine building locally via ARC-V979/978

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

what is the purpose of the seal water circ pump?

A

Seal water circ pump takes a suction on the respective silencer and discharges to the water cooler.
Flow then goes through a flow switch (for pump permissives) to the mechanical air removal pump where it is used for cooling and seal water.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly