1. AC ESS BUS is normally supplied by : AC BUS 1 AC BUS 2 EMER-GEN STATIC INVERTER
AC BUS 1
The EXTERNAL POWER has priority over the APU GEN :
Yes
No
Yes
Single-phase 115 V - 400 HZ AC power
In flight, on batteries only, the AC ESS SHED and the DC ESS SHED buses are lost :
Yes
No
Yes
5. In normal configuration, how is DC ESS BUS supplied ? From TR 1 From ESS TR From TR 2 From BAT 2
From TR 1
When A/C is in flight or on ground (speed < 50kt) and on batteries only
7. Normal minimum battery voltage before APU start is : 22 V 25 V 27.5 V No minimum
25 V
STATIC INVERTER
AC BUS 1 is powered by the GEN 2 because the GEN 1 line contactor opens
The EXT PWR is plugged in and external power parameters are normal
. A Generator Control Unit (GCU) controls :
Voltage of the generator
Frequency of the generator
both answers are correct
both answers are correct
12. In flight, in case of loss of all main generators, EMERGENCY GENERATOR not running, the STATIC INVERTER supplies : APU and ENG START + AC ESS BUS ENG START + AC ESS BUS + AC ESS SHED BUS ENG START
APU and ENG START + AC ESS BUS
The EMER GEN is driven hydraulically if the BLUE ELECTRIC PUMP is running
and the AC ESS BUS and the DC ESS BUS are connected to the emergency
generator
. When disconnecting the IDG the button should be pressed :
For no more than 3 sec
For longer than 3 sec
Until fault light goes out
For no more than 3 sec
What happens in case of total loss of main generators ?
The RAT is automatically extended and powers the YELLOW hydraulic system
which drives the EMER GEN
The RAT is automatically extended and powers the BLUE hydraulic system which
drives the EMER GEN
The RAT has to be manually extended and mechanically connected to the
emergency generator
The RAT is automatically extended and powers the BLUE hydraulic system which
drives the EMER GEN
In flight, in case of loss of all main generators, emergency generator running, the DC ESS BUS is supplied by the : HOT BUS ESS TR Both answers are correct
ESS TR
Both answers are correct
SHED during RAT deployement
No
Yes
Emergency generator is not supplying power when AC BUS 1 and 2 are not
powered
No
The APU
24. In cold aircraft configuration (No AC and no DC supply), where can the batteries voltage can be checked ? On the ECAM ELEC PAGE On The ELEC OVERHEAD PANEL There is no indication
On The ELEC OVERHEAD PANEL