Multiple Dwelling Law does NOT permit conversion of a LOFT building to an MD..
(ch 2 a1)
THEREFORE, the occupancy SHALL NOT EXCEED TWO SEPARATE individual units for living purposes
Following requirements shall be applicable:(ARTIST quarters)
-sign must be :
-metal 8 to 10 inches
-2 inch black letters/white background
-7 FEET above sidewalk level
-AS CLOSE AS POSSIBLE to MAIN ENTRANCE on front wall outside of building reading:
“AIR “ artist in residence
“3 F 3rd floor
“R rear
CDA (construction demolition abatement )
STANDPIPE SYSTEM REQUIREMENTS :
NEW BUILDING CONSTRUCTION
TEMPORARY STANDPIPE (becomes permanent )
EXISTING BUILDING (FULL DEMOLITION)
EXISTING standpipes in structures undergoing demolition shall be maintained as a dry standpipe
NEW CONSTRUCTION (depth of 75 feet or greater BELOW GROUND LEVEL)-STANDPIPE REQUIRED BUILDING
ALTERATION/PARTIAL DEMOLITION
note:
STANDPIPE PRESSURIZED ALARM SYSTEMS:
a2
Standpipe connection…
a2
–metal sign “standpipe connection”
RED LIGHT AT NIGHT
-if freezing conditions will occur, standpipe must be drained after use
SPRINKLER must also have RED light , if building under construction
COLOR CODING; building under construction…
a2
SPECIAL INSTRUCTOR will confirm compliance before walls are enclosed
ALL EXPOSED sprinkler/standpipe must be painted RED
Sprinkler systems ..
a2
–during DEMO–full/partial , maintained as NON automatic sprinkler system
RED PAINT maintained
During construction of NEW BUILDING , or spaces being added to existing building…
a2
AT LEAST ONE PERMANENT STAIR shall be brought to within a distance of 40 FEET or 4 floors below WORKING DECK
-IN ALL OTHER LOCATIONS where permanent stairs will be required a TEMPORARY or permanent staircase brought to within 40 feet or within 4 floors of working deck
ELEVATOR…whenever building reaches height greater than 75 feet…
A2
AT LEAST ONE ELEVATOR OR HOIST kept in readiness at all times for FD use
-max distance between highest ACCESSIBLE floor from a temporary elevator or hoist and the working deck of building under construction or demo shall be no more than 75 feet or 7 floors
*if travel hoist cannot be increased due to inclement weather, it shall be increased by end of next working day.
General…kindling, building, maintaining or using an OPEN FIRE IS PROHIBITED (burning of materials wherein products of combustion are emitted directly into the ambient air without passing through a stack or chimney from an enclosed chamber
a3
exceptions:
**COMMISsIONER may prohibit open fire OR the extinguishment of any open fire **
Open fires shall CONSTANTLY be attended until the fire is extinguished …
a3
MINIMUM OF ONE PORTABLE EXTINGUISHER /4-A rating or other approved on site fire extinguishing equipment, garden hose connected to an approved water supply
PATIO FIREPLACE…
A3
portable outdoor fireplace…solid fuel burning…should be DISCONTINUED IMMEDIATELY (no other enforcement at this time)
*if it is a chronic problem at the SAME LOCATION, discontinue and serve SUMMONS**
EXCEPTION: OUTDOOR /NATURAL GAS APPLIANCE: FIRE PIT(natural gas fueled and STATIONARY …no other fuel can be used )–they do not have venting system…primary function is aesthetic of the flame:
decorations, overhangs, awnings, sun control devices, etc.)
-not within 5 feet of exits or exit discharges
INSTALLATION:
PORTABLE BBQ (residential premises ) A3
GROUP R-2 OCCUPANCIES (APT. HOUSES, ETC.)
-only portable bbq designed for use with LPG containers, with a capacity of 16. 4 ounces may be stored or used on premises..INDOOR STORAGE OF LPG CONTAINERS LIMITED TO A MAXIMUM OF 4 PER DWELLING UNIT
GROUP 3 (1 or 2 family dwellings)
COMBUSTIBLE material storage…
–neat. orderly
-separated from heater/heating devices
-2 FEET OR MORE BELOW CEILING in areas of buildings not protected by sprinkler system, or minimum of 18 inches below sprinkler head deflectors in areas protected by sprinkler
NO SPRINKLER (2 FEET OR MORE BELOW)
SPRINKLER (18 INCHES BELOW sprinkler heads )
SHAFTWAY MARKINGS
A3
-SHAFTWAY in RED LETTERS ON WHITE BACKGROUND, 6 INCHES HIGH
ROOTOP CONDUITS AND PIPING…
A3
COLOR CODED:
HIGH VOLTAGE-RED
LOW VOLTAGE -ORAGNE
NATURAL GAS PIPING-YELLOW (natural blonde)
OTHER COMPRESSED GAS PIPING (YELLOW . labeled at regular intervals with type of gas)
FUEL OIL PIPING –YELLOW WITH BLACK STRIPES
In Group R-1 and R-2, with more than 8 dwelling unit on a floor, a sign shall be posted in the elevator lobby or other public entry on each floor and in the public corridor opposite each stairwell entrance , identifying by directional arrows and dwelling unit numbers/letter, the direction to each dwelling.
A3
signage not needed in public entry when entrances to dwellings are located in a single direction
Multifloor dwelling (duplex/triplex) A3
identified on the DOOR JAMB on public corridor side, , NOT MORE THAN 12 INCHES from bottom of the door, indicating dwelling unit number and /or letter. AND every door of each such multifloor dwelling unit that opens to a public corridor or other means of egress should be identified on public corridor side of the door by ONE OR MORE UPWARD OR DOWNWARD POINTING ARROWS INDICATING THE DIRECTION OF THE OTHER FLOORS
FLAMMABLE liquids in any amount SHALL NOT be stored in basements, or other areas below grade.
A3
COMBUSTIBLE liquids shall be allowed to be stored in basements, cellars, or other areas below grade provided that these areas are protected throughout sprinkler system.
-must be segregated vertically and horizontally with 2 hour fire resistance rating
BULK PLANTS AND TERMINALS (COMBUSTIBLE LIQUIDS)
A3
-standpipe/yard hydrant systems red with contrasting white bands -automatic sprinkler systems red with bright green bands nonautomatic sprinkler system (including fog sprays) red with aluminum bands Carbon Dioxide extinguishing systems red with contrasting brown bands Steam extinguishing systems red with black bands Foam extinguishing systems red with bright orange bands
ILLEGAL storage of LPG is enforced with ..
A3
IMMEDIATE SUMMONS and CONFISCATION through vendor or fdny
LPG permit obtained for storage, handling , use or more than 400 scf (standard cubic feet) of LPG (46 pounds of propane)
LPG containers shall nOT be used in basement, pit or other area below grade..
*a SINGLE LPG CONTAINER with a capacity not greater than 16.4 ounces may be used below grade for emergency indoor repairs, provided that the container is NOT left unattended
A3
LPG containers shall not be used in an above grade underfloor space or basement unless such location is provided with an approved means of ventilation
DO NOT STORE LPG CONTAINERS ON ROOF.
A3
DO NOT STORE, HANDLE, OR USE LPG for a stationary LPG installation in any area where access to piped natural gas from a public utility is available
Storage of portable LPG containers in buildings accessible to PUBLIC..
A3
STORAGE in buildings UNACCESIBLE TO PUBLIC..
–storage in areas not more than 300 lbs and separated areas by minimum of 300 feet