BLEED TRIP LIGHT
-at a temperature of 490degrees
And/or
- at a pressure of 220psi
The bleed air valve closes
DUAL BLEED LIGHT
Will illuminate when
1) APU bleed air valve is open and the number 1 engine BLEED air switch is ON
2) APU bleed air valve is open, the number 2 engine BLEED air switch is ON and the isolation valve is open
APU Bleed air can be used
Altitude
17000’
Which side of the pneumatic manifold normally receives external ground air?
Right
With the ISOLATION VALVE switch selected to AUTO, the valve will open when:
Either PACK switch is selected OFF, or either engine BLEED Air switch is selected OFF
WING BODY OVERHEAT
There is a bleed air leak in one of the 8 sensor zones