Heat Generated by Fuel
Qa= mf HHV
Rated Boiler Horsepower, RBH
for water tube: HS/0.91
for fire tube: HS/1.1
Developed Boiler Horsepower, DBH
ms(hs-hf)/35,322 in HP
Percent Rating, %R
DBH/RBH ×100
ASME Evaporation Units
ms(hs-hf), kJ
Factor of Evaporation
(hs-hf)/2257
Boiler Efficiency, n
ms(hs-hf)/mf HHV
net boiler Efficiency, n net
(ms(hs-hf)-aux)/mf HHV
Actual Specific Evaporation
ms/mf
Equivalent Evaporation, EE
ms×FE
Equivalent specific evaporation, ESE
(ms/mf)×FE
1kgf/cm² to kPa
98.0665