BUSTIE OPN
if one GEN AMPS value shows XXX
if both GEN AMPS show XXX
2. Double GEN DISCON procedure
30min on battery
BAT DISCON
CAD DEGR
CAD FAN
Do not start
CPDS OVHT
if caution remain ON
4. land within 30 min
DEGRADE
system I and/or II
Caution:
After landing
ENG CHIP
” ON GROUND”
“1. Eng ident”
“2. Single eng emer shutdown”
“ON FLIGHT”
“1. OEI flight condition”
2. ENG CHIP sw. - BURN 1”
3. Chip pulse event record
If ENG CHIP remain ON
“4. Eng ident”
Alternative 1: “Single eng emer shutdown”
Alternative 2: “ ENG main sw. - IDLE”. If needed for landing
6. LASA PRACTICABLE
If ENG CHIP extinguish a second activation will be authorised
ENG CHP CT
ENG CHIP CAUTION IS NOT AVAILABLE
ENG FAIL
1 “ OEI flight conditions”
2 “ affected eng Ident”
3 “ Single eng emer shutdown perform”
4 LASA PRACTICABLE
ENG O FILT
1- eng Oil t&p Monitor
2- LASA PRACTICABLE
ENG OF CT
Eng O Filt caution is not available
Do not start
FIRE EXT
Fire extinguishing system is active
FADEC FAIL
1-“Collective lever Adjust to maintain NRo within normal range”
2-“Affected eng Ident by small chge”
3-“Respective TWIST GRIP Adjust slowly to set
80% (+-2%) N1 on the affected eng
Simultaneously adjust collective to maintain
eng within limits.
(When the OAT is below –10_C, adjust N1 to 77% ($ 2%) instead of 80%.)
AND AVOID QUICK TWIST GRIP ROTATIONS. HOLD MIN. 10% TORQUE ON THE NORMAL ENGINE TO MAINTAIN AUTOMATIC CONTROL OF VARIABLE NRO IN ACCORDANCE WITH SECTION 7, FLM EC 135 T2 (CPDS).
FLI DEGR
1- do not try to match the needles when different parameters are designated as first limit
Avoid using max Pwr. Use the needle of the other engine for limit indication
2-LASA PRACTICABLE
FLI FAIL
2. LASA PRACTICABLE
F PUMP AFT and FWD
F PUMP AFT
1- Fuel level main tank Chck
Qty ok
2- FUEL PUMP XFER-A sw ON
3- XFER-A pump cb Chck in
If remain on
4- FUEL PUMP XFER-A sw OFF
QTY LOW
2- FUEL PUMP XFER-A sw OFF
in hover condition the unusable fuel can be up to 71 kg
Qty unusable can be reduce to 7.5 kg when flying with 80 kias or more
F PUMP FWD
1- Fuel level main tank Chck
Qty ok
2- FUEL PUMP XFER-F sw ON
3- XFER-F pump cb Chck in
If remain on
4- FUEL PUMP XFER-F sw OFF
QTY LOW
2- FUEL PUMP XFER-F sw OFF
in forward flight condition the unusable fuel can be up to 59 kg
Qty unusable can be reduce to 3.6 kg when flying with 80 kIAS or less
F QTY DEGR
The degraded fuel qty indication represent the minimum fuel level within pitch attitude range -3 +6
Set pitch between 0 +/-1 before reding fuel qty, the calculate remaining flight endurance
F QTY FAIL
The fuel qty has failed
DO NOT calculate flight endurance according the fuel qty indication
Fuel qty information only by LOW FUEL warning
LASA PRACTICABLE
FUEL
1- fuel qty chck
If fuel in the main
2- FUEL PULP XFER-A-F Chck on
If 0 in the main
2- FUEL PULP XFER-A-F Chck oFF
3- LASA PRACTICABLE
FUEL FILT
“One caution”
LASA PRACTICABLE
“Both caution”
“LASAP”
FUEL PRESS
1- FUEL PRIME PUMP sw ON
2- LASA PRACTICABLE
be prepared for eng failure
FUEL VALVE
LASA PRACTICABLE