Describe the Circulating Water System Big Picture Flowpath.
Ocean => Two 12 foot ID concrete pipes => Intake Canal => Coarse Screen (Trash Rack) => Traveling Screen => CW pump => CW pump discharge valve => Debris Filter System => Condenser to the Condenser Outlet Valve => Two Sealwells (A1 & B1 waterbox go into same Seal Well) => Discharge Canal => 12 foot ID pipe that splits into two 7 foot ID pipes to the ocean
When do the Screen Wash pump(s) automatically start?
In Auto: Both pumps start when there is a 6” level deviation between upstream stationary screens and downstream travelling screens.
Describe the travelling screen auto start.
A pressure switch starts all screens in slow speed when it detects water from the pumps.
What causes a travelling screen to switch to fast speed?
The affected screen will switch to fast mode when level deviation is 10”.
Describe the Condenser Waterboxes.
A1 & B1 (A2 & B2) Waterboxes discharge to the same Seal Well
Each waterbox has a pump supplied from A and B bus
(i.e. if you lose 1A2 or 1B2 4160v bus, you will still have flow through A and B Waterboxes)
Each have a SJAE suction piping penetration which extends into the center of the tube bundle
Describe Condenser Water Box Priming.
Describe the Waterbox Vacuum Breakers.
Describe the Condenser Integral Tubesheet Pressurization System.
Describe the Debris Filter System (DFS).
Describe the Condenser Tube Cleaning System (CTCS).
Describe the Circulating Water Pumps.
122,650 GPM each
* Propeller Type Pump - (Amps Increase if waterbox fouling occurs)
* Air Cooled Motor, Lubricated by ICW (or domestic water system)
* Disch Press ~ 17 psig
* Power - A1 / B1 CW pumps - A2 4160 Bus, A2 / B2 CW pumps - B2 4160 Bus
* RTGB Handswitch controls both the CW pump and the discharge valve
* Pump and discharge valve also controlled locally from individual handswitches
What are the power supplies to the Circulating Water Pumps?
A1 / B1 CW pumps - A2 4160V Bus
A2 / B2 CW pumps - B2 4160V Bus
Describe the Circulating Water Pump Start Interlocks.
BIG PICTURE OVERVIEW: Pumps are interlocked based on which are connected to the same discharge tunnel - (A1 & B1) and (A2 & B2)
1st Pump Start:
* Control Switch or PB taken to start
* Discharge valve strokes to 30% open, then Pump starts and
* Discharge valve remains at 30% for 15 minutes, then fully opens
2nd Pump Start:
* Control Switch or PB taken to start
* Discharge valve strokes to 30% open
* Discharge valve remains at 30% for 5 minutes, then fully opens
Describe the Circulating Water Pump Detailed Starting Logic.
(A1 & B1 start logic described – Assume you are starting the A1 CW pump)
The ‘A1’ Circ Water Pump will start if:
* The ‘A1’ Circ Water Control Switch taken to “START” or the Local ‘START” pushbutton pressed
AND
* The ‘A1’ CW Pump Discharge Valve has been closed for at least 2 min
* The ‘A1’ CW Pump Lube Water Pressure / Flow > 8 gpm
* The ‘A1’ CW Pump condenser outlet valve is 100% open
* The ‘A1’ CW Pump discharge valve reaches 30% open
* The ‘A1’ CW Pump breaker is racked in
* The ‘A1’ CW Pump Waterbox Vacuum breakers are closed
AND
Describe the Circulating Water Pump Discharge Valves.
What are the CW Pump Discharge Valve Opening Interlocks?
Fully closed for a minimum of 2 minutes
Associated Waterbox vacuum breaker valves are fully closed
Parallel pump discharge valve fully closed or fully open for 60 seconds if running
Describe Important CW Pump Starting Info.
If All Pump Start Interlocks are made up:
* Discharge valve opens 30% and then the CW pump starts
* On pump start, personnel are stationed to open valve breaker if the valve travels past its 30% mark
* After 5 minutes, the Pump discharge valve then slowly fully opens (parallel pump running) or after 15 minutes (parallel pump not running)
* Wait at least 1 minute after First Pump’s discharge valve gets to full open before attempting to start a second CW pump OR the First pump will trip
* If running pump trips w/in 5 minutes of starting the second pump, the second pump trips
* Allow 60 minutes between starting pumps (prevents slumping)
The general startup logic for the circulating water pump(s) was designed to:
a) Gradually introduce water to prevent water hammer and to minimize starting loads on the pump motor.
b) Prevent backflow into the parallel pump should it be inoperable.
Describe the Circulating Water Pump Start Permissive Light.
CW Pump Amber Permissive Starting Light – (comes on when these permissives are met)
* Breaker racked in
* Condenser Outlet valve is full open
* Lube Water Flow > 8 gpm
* Normally out when the CW pump is running since the breaker is closed
Describe the Circulating Water CW Pump Stop Logic.
(The discharge valves automatically close on all pump stops/trips)
Manual:
* Control Switch or Local P/B to “STOP”
Automatic:
* 2nd pump trips within 5 minutes after starting it
* Overcurrent
* 4.16 KV Bus U/V
Describe Circulating Water System “Pull-To-Drain”.
Pull-To-Drain:
* Closes discharge valve & Condenser Outlet Valve
* Opens Inlet & Outlet Waterbox Vacuum Breakers
* Re-Opens CW pump discharge valve to drain the Waterbox
* Prior to returning control switch from Pull to Drain to Normal, CWP breaker fuses must be removed or the CWP discharge valve breaker must be OPEN. Prevents TRIPPING running CWP in opposite train.
What is required when starting CW Pumps with 1 Ocean Intake Pipe Out Of Service?
Space starting of CW pumps at least 90 minutes apart.
Discuss CW Pump Shutdown.
First Pump
* Place switch in STOP
* Pump stops and discharge valve closes
* Waterbox vacuum breakers remain closed
* Wait at least 1 minute after discharge valve is closed
* Condenser Hotwell level may be unreliable if the Main condenser is under a vacuum and less than 4 Circ water pumps are in service. Closely monitor hotwell level and isolate make-up sprays as necessary or adjust vacuum drag (per NOP) to maintain hotwell level < 3’ 8” by local sightglass indication. If hotwell > 3’ 8” by local sightglass indication and negatively impacting condenser backpressure, AOP directs to reduce turbine load until level restored below 3’ 8”.
Second Pump
* Place switch in STOP
* Pump stops, Discharge valve stays open
* Waterbox vacuum breakers open, and re-close 5 minutes later
* Steam Supply to Aux Priming Ejectors close
* Discharge valve closes
Discuss CW Pump Shutdown To Clean Waterboxes.
Describe the actions for CW Pump Trip.