Valsalva manouver
increases CO
ventilation
Positive pressure on heart and lungs
-CO goes down
If there is a hole in the ventilator bellow
Dog will get light plane of anesthesia
Ascending bellow is a little better than
descending bellow
-easier to see if patient has become disconnected
Compliance =
change in Volume/Change in Pressure
Indication for ventilator
If trachea collapses on expiration
it collapses intrathoracically
If trachea collapses on inspiration
it collapses extrathoracically
Recruitment
Treatment for aspiration pneumonia
use PEEP
PEEP drops
Cardiac output
-saving the lugs but sacrificing the heart