CP4 Equipment List
CP4 Method
Why can you not use a light gate in CP4?
Liquid will block beam and difficult to get ball to fall directly through the beam.
The liquid is coloured and the low intensity of the light transmitted will make the timing
unreliable. It is likely that the ball will not fall through the relatively narrow beam of the light
gate
Potential Errors for CP4
Systematic
- Ruler must be clamped vertically straight
Random
- Cylinder should have large diameter compared to ball to ensure laminar flow
- Ball must fall in centre to avoid pressure differences caused by being too close to wall; affects velocity
Safety measures CP4
Mop spilled liquid
- Easier to slip on floor; mop any spills
Goggles
- Avoids splashes in the eye
Clamp measuring cylinder
- Cylinder not stable; clamp so doesn’t fall
How to increase accuracy of CP4?
Smaller balls and viscous fluids
- Will take longer for ball to fall; more accurate timing
Increase values of readings
Video analysis
- More accurate timing