CT GENERATIONS Flashcards

(32 cards)

1
Q

CAT

A

Computerized Axial Transverse/ Tomography

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

o - Hounsfield build a whole body CT SCANNER

A

1975

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

o 1971: EMI ( ____
Introduced by SIR GODFREY HOUNSFIELD

A

Electrical Musical Instrumentation)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

FEATURES if 1ST CT > scanning motion or tube detector movements

A

TRANSLATE- ROTATE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

1st CT

Detector & Xray source:
X-ray Beam:
Duration of Scan ( average):

A

Single
Pencil- shaped
25-30 mins

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

mins to scan one slicein 1st CT

A

3-5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

: minute to reconstruct

A

1.5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

1st CT SCAN

Number of Slice per rotation:
Motion of Gantry:
Scan Mode: step and shoot scanning
Power Supply: straighten twisted system cables
Characteristics:made up of ____

A

1
Linear and Rotary
Sodium Iodide

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

1st CT
 ___ translations with __ degree rotation in LINEAR MOTION

A

180
1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

2nd Generation
Tube- detector movement:

A

Translate Rotate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

2nd CT
introduced by ___ @ Georgetown University in Feb. 1974

A

LEDLEY

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

2ND CT
the machines utilizes ___ PMT. Complete a scan in only 9 TRANSLATE- ROTATE CYCLE.

A

30

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Xray beam shaped of 2nd CT
___ secondd per slice

A

Narrow fan beam
20

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

___ translations in CT

A

60

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

No. Of detector in earlier and late version of CT

A

3, 53

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

3rd generation introduced in year

17
Q

3rd generation of CT with ____ shaped beam 40 to 60 deg

18
Q

Xtube and detector of 3rd generation

A

Rotate rotate

19
Q

 Larger array of detectors (more than __) were used. Scanning time was reduced to 2 seconds
Of 3rd generation

20
Q

 Third generation had been proven by the-study of

A

Mathias Meyer

21
Q

 spiral scanning This is the most commonly used method today and takes about __ seconds to image a single slice

22
Q

 DISADVANTAGE: of 3rd generation

A

RING ARTIFACT.

23
Q

Duration of scan
(average): approximately __sec ( 3rd)

24
Q

4th generation
Year
Scan

25
Source detector movement of 4th generation
Rotate stationary
26
Number of detector ka 4th generation
4800
27
Rotation degrees of 3rd generation
360
28
Tube detector of 5th generation
Stationary stationary
29
EBCT ___ GENERATION
5th
30
1990s helical or spiral CT
6th generation
31
Slip ring technology 5s rotation scan More 360 deg
6th gen
32
Eliminate 6 scan delayed
6th gen