E-3
What are the major action catagories in E-3, include order?
E-3
If both MD AFW pumps are OOS and only steam supply available to TDAFW is from a ruptured S/G, will you use contaminated water to run the TDAFW pump?
If you have a faulted, ruptured S/G what L s/g will you try and maintain for affected S/G?
YES, it would be worse to not have a heat sink than to have an unmonitored release
None, you do not feed a faulted S/G (even if it is ruptured)
E-3
What level do you maintain for a ruptured S/G?
Why?
E-3
Once you commence depressurizing to stop the breakflow in SGTR, what is the “Depressurization Termination Criteria”?
AND
OR
OR
E-3
Upon completing E-3 what are the three procedures, order of preference and advantages/ disadvantages to each that you can transition into for Post SGTR c/d?
E-3
If the RCPs are not running and you commence a cooldown and depressurization…..
What CSFST may be invalid?
What do you do if you recieve this indication?
Tc for the ruptured loop may give you a false red or magenta path
disregard Tc indication untill C/D, depress, and terminate SI is complete