(88) Location and function of the ground service switch:
MD-88
• APU PWR switch and EXT PWR switch, both located on overhead panel, remove and select their respective power to ground service bus.
(90) Location and function of ground service switch:
MD-90
Ground Service Power Switch, located on ovhd panel, performs following functions:
• OFF - Disconnects APU or external power from AC tie bus to ground service bus.
• ON - Connects APU or external power from AC tie bus to ground service bus, provided right generator bus is not powered.
- APU power has priority over external power for powering ground service bus.
(88, 90) Essential electrical equipment that may be powered during a complete loss of normal electrical power when positioning EMER PWR switch to ON or ARM(90):
(88, 90) When does the battery charger operate?
(90) Time limitation on starting APU on initial electrical power up. Why?
On initial electrical power up (MD-90), crew must wait 90 sec before starting APU
(88, 90) How to connect APU generator to electrical system:
(88) Meaning of each blue light on MD-88 electrical panel
(90) Meaning of each blue light on MD-90 electrical panel
(88, 90) Where are voltage, frequency and amps read?
• AC VOLTS Meter, FREQUENCY Meter, and AC LOAD Meter are located on Electrical Power Panel of Forward Overhead Panel. DC Volts, Amps and Loads are adjacent to AC indicators.
(All) Components powered by the ground service bus:
Ground service bus provides power to only those circuits necessary for ground servicing.
(88, 90) How long do batteries last on emergency power?
(88) Function and positions of A/C BUS X TIE Switch:
AC Crosstie system has 3 functions:
• Prevents paralleling.
• Powers unpowered generator bus.
• Isolates generator bus faults.
NOTE: Under certain fault conditions, AC crosstie relay will lock open.
(90) Function & positions of BUS TIE switches on MD-90:
(88, 90) Positions and function of DC BUS X TIE Switch
(88, 90) Positions, function of EMER PWR switch (MD-88)
OFF - Removes batteries as source of emergency power.
ON
(88, 90) Positions, function of EMER PWR switch (MD-90)
• ON - Emergency power is energized, prevents battery charger operation. Batt. supplies pwr for AC emer bus (through emer inverter), DC emer bus and DC transfer bus.
(88, 90) Positions and function of BATT switch:
(88, 90) Normal AC power voltage and frequency for engine driven generators:
* 400 ± 4 Hz