Why is DC unsatisfactory for SMs main distribution system?
Name typical 115V Essential loads
A: Lighting
B: Tank contents
C: Anti-condensation heaters
Name typical 115V Non-Essential loads
A: Equipment sockets
B: Domestic equipment
Name 5 power sources available to a V-Boat
A: 265DC (nominal) main battery, 17600 Ah @ 5-hour rate
B: Two 3MW turbo-generators
C: One 850kW AC diesel generator
D: One 750kW DC diesel generator
E: AC shore supplies, comprising eight 400A AC rated cables, 4 aft and 4 fwd, split port and starboard
*How do we protect against the main types of damage?
Mechanical- Strict restrictions on warm up and cool down rates
Chemical- Strict chemical limits with constant monitoring to allow corrective action if necessary
Thermal- Heat constantly removed, again constantly monitored to be shutdown if necessary
What are the different colours on the MSC BITE monitoring system?
What do they mean?
Green- within correct tolerance
Amber- warning of a fault that may lead to a trip
Red- an out of tolerance reading and trip
Blue- mode indication
Describe the AC and DC parts on MG and what controls them
The battery must always be available as the reserve source of power, briefly tabulate the process required to carry out a CD.
A- The battery is put through a charging cycle and the purposely discharged in a controlled manner to a low state of charge. To complete the process, it is then recharged to full capacity. This improves its condition and provides a capacity check.
Name the occasions in when welding, burning or grinding must be stooped
A- The battery is above gassing voltage (288V)
B- Battery temperature exceeds 46c
C- Less than 1 hour has elapsed since completion of charge
D- H2 contents meters indicate a H2 concentration of 2% (EOOW to be informed whenever concentration reaches 1.5%)
E- Loss/reduction in airflow, or equipment failure ie LP blowers (VS yellow), whilst charging.
What are the pre requisites for a battery charge alongside?
5 tripping conditions for the DG DC Bkr
A- IPBS OFF/Reset switch B- Breaker manual push to trip switch C- Low voltage D- Overcurrent E- Reverse current F- Speed below 200rpm
5 tripping conditions for DG AC Bkr
A- IPBS OFF/Reset Switch B- Breaker manual push to trip switch C- Low voltage D- Overcurrent E- Generator Fault F- Reverse power G- DG excitation OFF/ON Switch
Briefly explain what the AC and DC diesels are, ratings, type etc
AC generator consists of a brushless rotating field altinator, rate 850kw
DC diesel generators is comprised of a shunt wound, 8 pole self exciting type and is coupled to and driven by a paxman valenta diesel engine which spins at 1200rpm
How many cables are used for SS
DC system uses 4 cables
AC system uses 8 cables
When would you connect DCSS?
3 differences between AC and DC Bkr
Two types of ACB
IFR6
IFR3
IF6
List supplies or converted supplies found onboard
450 60hz
265v
115v
160v DC
List 4 typical 115 ESS or NON ESS loads
Most common is LIGHTING, others:
What audible alarms do we have that require immediate attention?
Procedure for 440v earth checks
-Select the Port/Off/Stbd switch to the side required
-Position the required switch to CAL
-Depress read indicator button and check indication on ohmmeter is within red sector, if not investigate
- Select the service to be earth checked on the port select or stbd select switch as required
- Depress the read indicator and check the resistance to earth indicator on the ohmmeter. Readings of less than previous or expected levels are to be investigated.
If an earth fault is detected inform EOOW/EOOD immediatley
Methods of propulsion, where are they controlled/
Electrical propulsion motor
Secondary propulsion motor
Controlled from hydraulic manifold in the Engine Room and Remotely from the ESP in the Manoeuvring Room
What are the different types of compartment lighting and their supplies?
Primary source is 115V 60hz fluorescent bulb supplied from the essential busbars via transformers.
Secondary source 265V DC incandescent lighting supplied from the battery side of the battery breakers.
Emergency source is the automatic emergency lantern supplied via own built in power source chargeable batteries.