ENG 1 2 FIRE pb - Released
Silences CRC Arms squibs Closes Hydraulic Shutoff Value Closes LP fuel value De-energizes FADEC Deactivates IDG Closes Bleed Value Closes Pack flow control value
APU FIRE pb - Released
Silences CRC Arms squib Closes LP fuel value (APU shuts down) Turns off APU fuel Pump Deactivates APU Generator Closes APU bleed value Closes X Bleed Value
Agent 1 2 - SQUIB light (White)
Squib is armed (after FIRE pb popped)
Agent 1 2 - DISCH light (Amber)
Bottle empty
ENG 1 2 Test pb - Pushed
CRC and Master warn light ECAM ENG Fire pb light Squib light Disch light Fire light on ENG panel
APU Test pb - Pushed
CRC and Master warn light ECAM APU fire pb light* Squib light* Disch light* (* If DC power only)