EMER ENG SHUTDOWN
Abort Start
Fire on start
Abort start (then alternate motoring engines until rotors are stopped to reduce possibly of residual fire)
Residual Fire During Shutdown
Engine Compartment, APU, Fuselage or Electrical Fire - Ground
In-Flight Fire Procedures
APU Fire - Flight
Engine Fire - Flight
Electrical Fire - Flight
After landing, batt switch off is not memory item
Smoke and Fume Elimination
… 2 more items non memory Cargo loading ramp as req and co pilots sliding window - closed
Emergency Descent (High Speed Straight Ahead Descent)
Out of trim descent
Low speed maneuver descent
Ditching
Power off- Autorotate
Power on-
1. Land in water away from personnel
2. Emergency ENG shutdown
Landing in Trees
Power on-
1. Approach to a hover 5-10’ above tree level
2. EMER ENG SHUTDOWN
Power off-
1. Approach to hover 5-10’ above tree level
2. EMER ENG SHUTDOWN
3. AUTOROTATE
Dual Engine Failure ENG 1 and 2 FAIL
Cruise:
1. AUTOROTATE
2. External cargo - Jettison
3. ALT switch - disengage
Single Engine Failure (ENG 1 or 2 FAIL)
non memory If continued flight is possible:
4. Land as soon as practicable
5. Emer ENG shutdown (when conditions permit)
Engine Restart During Flight (has stars on 1 and 7)
Engine Compressor Stall
No memory items
FADEC 1 or 2 Caution
Non memory, Reduce rate of thrust CONT lever changes
FADEC 1 AND 2 Caution
Non memory, reduce rate of thrust CONT lever changes, land as soon as practicable
Engine Fluctuations or Excessive Torque Splits without FADEC 1 or 2 Caution
If not corrected
More to do that are non memory items
REV 1 and/or 2 caution without associated FADEC 1 and/or 2 Caution
Do not manually select reversionary mode on affected engine as uncommanded power changes may occur
REV 1 or REV 2 Caution (s) (with) associated FADEC 1 and FADEC 2 Caution
If power required for flight
1. Land as soon as possible
2. Emer eng shutdown as required
If dual power not required
1. Emer Eng shutdown as required
2. Land as soon as practicable