Problems with loose fitting lenses? (5)
Problems with tight fitting lenses? (6)
Problems with spherical RGP on highly astigmatic corneas? (5)
Bennet’s design tricurve and quadcurve
Tricurve:
SCR: add 1.0-1.5mm to BC/0.3mm wide
PCR: add 1.5-2.0 to BC/0.4mm wide
Quadcurve:
SCR: add 0.8mm to BC/0.3mm wide
ICR: add 1.0mm to BC/0.2mm wide
PCR: add 1.4 to BC/0.2mm wide
A change in radius of ___mm results in ___D of change
0. 50D
Symptoms of ghosting, flare or diplopia can be due to what?
pupil not being fully covered by optic zone
What are characteristics of a lens that is too small (3)
What are characteristics of a lens that is too big? (4)
Large lenses can be particularly problematic when associated with?
high Rx due to thick centre or edges
What are the typical TD/OZ combinations?
<9.00mm (7.0)
9.0-9.3mm (7.5)
9.5-9.8mm (8.0)
>9.8mm (8.5)
To counteract the BC becoming steeper when increasing TD, what should happen to the BC for every 0.5mm increase in TD?
BC should be made 0.05mm flatter (0.25D)
increasing/decreasing TD makes the lens steeper/flatter causing changes in power. What rule is used to help counteract this?
SAM FAP
steeper add minus, flatter add plus
increasing/decreasing TD also has an effect on what other fitting characteristic?
edge lift
increasing TD = increase edge lift
decreasing TD = decrease edge lift
Summarise the effects of a large lens (5)
Summarise the effects of a small lens
What parameter has the most influential change on edge lift?
changing SCR
ideal edge lift width?
0.3-0.5mm
How can you modify a high plus power RGP to counter inferior decentration?
add minus carrier on edge
how can you modify a high minus power RGP to counter lid interaction problems?
add plus lenticular –> wedge shape
Why is PMMA a good material to use as a trial lens? (3)
- has no surface charge
When would you consider a lower Dk RGP material? (2)
- to reduce flexure
Dimple veiling etiology, signs and management
etiology: gas bubbles trapped in a large post-lens tear film caused by lens being too steep centrally and/or too much edge lift peripherally. Bubbles act like solids and cause pits in the epithelium.
- pool with NaFl
- if significant can cause irregular corneal topography
- decrease vision when located centrally
Mx:
reduce post-lens tear film clearance by reducing sagittal height (if central) or reduce edge lift if source of bubbles from high peripheral tear reservoir
Corneal warpage etiology, signs, symptoms, management
etiology:
- mostly mechanical
- associated underlying cause is prolonged oedema
- ill-fitting lens
signs:
- corneal topographic shape change
- distorted keratometry mires
- irregular retinoscopy results
- indecisive subjective refraction
- reduced BCVA in spectacles
- spectacle blur
symptoms:
Mx:
Corneal rehabilitation
- change to lenses with increased Dk/t and cease CL wear
- repeat refraction and topography 1-2 weekly until changes stabilise
- withdrawal of original lenses and final refitting
Peripheral corneal staining (3 and 9 o’clock) etiology, signs, symptoms, Mx
etiology:
- lens edge miniscus causing local tear film thinning leading to exposure of the cornea
signs:
symptoms:
Mx