IR 1/2/3 steady fault
Fault in IR
ADR 1/2/3
Fault in Air Data
ELAC 1 2 (Elevator Aileron Computer)
- Fault
SEC 1 2 3 (Spoiler Elevator Computer)
Fault
FAC 1 2 (Flight Augmentation Computer)
Fault
“GPWS” TERR pb
EGPWS failed
“GPWS” SYS pb
Modes 1-5 failed
“APU” MASTER SW pb
Auto shutdown for many reasons
Fire will only cause auto shutdown on the ground
“CABIN PRESS” MODE SEL pb
Both Auto systems failed
“ANTI ICE” WING pb
“ANTI ICE” ENG 1 2 pb
- Valve in transit
PACK 1 2 pb
* Disagreement of valve position
ENG 1 2 BLEED pb
L- Leak O- Overheat O- Overpressure downstream S- Start in process and valve not closed A- APU Bleed On and valve not closed
APU BLEED pb
Leak
“AIR COND” HOT AIR pb
Overheat detected, and closes:
- Hot air valve - Trim Air valve
BAT 1 2 pb
Battery Charger current is out of limits
GALLEY pb
Any generator load > 100%
IDG 1 2 pb
- Low Oil Pressure (inhibited below 14% N2)
GEN 1 2 pb
- Line contactor open (other than by pb)
APU GEN pb
AC ESS FEED
AC ESS Bus not powered
RAT and EMER GEN
Emergency Generator is not supplying power, but should be (AC1 and
AC2 are not powered)
LTK PUMPS 1 2
RTK PUMPS 1 2
Low output pressure
CTR TK PUMP 1 2
Low output pressure