City Population (2017)
226,551
City Budget (2017)
$289.4 million
FFD Budget (2017)
$46.5 million:
97% general fund
2% paramedic tax
1% grants
38.6 million salaries and benefits
Automatic Nozzle: GPM range GPM we flow Nozzle pressure Pressure pumped at Nozzle Features and construction
50-350 gpm We flow at 200gpm 100 psi nozzle pressure 160 psi for 150' crosslay Feature High and Low pressure mode (100 and 55 psi) Selectable Gallonage (65,110,150,200,200,210) Constant Pressure Stainless Steel Slide Valve Extruded aluminum body Debris Screen 5/16"
Fremont Nozzle Types and GPM ranges
Automatic (50-350) Midforce (70-200) Dual Force (70-250) Attic Nozzle (90) Ultimatic (10-125) Featherlite (20-95)
City Manager
Fred Diaz
City Mayor
Lily Mei
City Council
Rick Jones (assistant mayor)
Vinnie Bacon
Raj Salwan
David Bonaccorsi
Station Addresses
1 - 4200 Mowry Ave (x of Argonaut)
2- 37299 Niles Blvd (x of G st)
3 - 40700 Chapel Way (x of Fremont Blvd)
4 - 1000 Pine St (x of Paseo Padre Pkwy)
5 - 55 Hackamore Ln (x of Warm Springs Blvd)
6 - 4355 Central Ave (x of Dusterberry)
7 - 43600 South Grimmer Blvd (x of Automall Pkwy)
8 - 35659 Fremont Blvd (x of Nicolet Ave)
9 - 39609 Stevenson Pl (x of Stevenson Blvd)
10 - 5001 Deep Creek Rd (x of Paseo Padre Pkwy)
11 - 47200 Lakeview Blvd (x of Gateway Blvd)
Corps Yard Address
42551 Osgood Rd
Training Tower Address
7200 Stevenson Blvd
FFD HQ Address
3300 Capitol Ave
Station Phone Numbers
510-791-430_ or 4310 or 4311
Dual Force Nozzle: GPM range GPM we flow Nozzle pressure Pressure pumped at Nozzle Features and construction
70-250 gpm We flow at 200gpm 100 psi nozzle pressure 200 psi for 250' pre-connects Feature High and Low pressure mode (100 and 55 psi) Selectable Gallonage (65,110,150,200,200,210) Constant Pressure Stainless Steel Ball Valve Twist Shut-off Valve Break-away Tip for extending a line Extruded aluminum body Debris Screen 5/16"
Mid-Force Nozzle: GPM range GPM we flow Nozzle pressure Pressure pumped at Nozzle Features and construction
70-200 gpm We flow at 125gpm 100 psi nozzle pressure 153 psi for 150' crosslay (1 1/2" line) Feature High and Low pressure mode (100 and 55 psi) Selectable Gallonage (65,110,150,200,200,210) Constant Pressure Stainless Steel Slide Valve Extruded aluminum body Debris Screen 5/16"
Blitz Fire: Tips sizes and GPMs elevation degrees side to side degrees weight safety feature
1" - 300gpm 1 1/4" - 400gpm 1 1/2" - 500gpm Fog nozzle 100-500gpm 10 degrees up 50 degrees down 20 degrees side to side 22lbs 1G of sideways acceleration Tungsten carbide tipped leg spikes 10' hose straight back
Ground Monitor: Tips sizes and GPMs elevation degrees side to side degrees weight safety feature
1 3/8" - 500gpm 1 1/2" - 600gpm 1 3/4" - 800gpm 2" - 1000gpm Fog nozzle 150-1250gpm 90 degrees of elevation up 35 degree safety pin down (dismounted safety) 45 degrees side-to-side for safety while dismounted 48lbs Tungsten carbide tipped leg spikes 10' hose straight back
Streets that compose “5 corners”
Fremont, Union, Washington, Bay
DryChem Extinguisher: Class Agent Range Duration Sweep Method Amount Service By
Inspection
20A120BC Mono ammonium phosphate 16-20ft 10seconds fast side-to-side breaks up chemical chain reaction 20lbs of dry chem, 35lbs 7oz total cylinder Service by station 1C
Inspect the pressure gauge, turn upside down to prevent dry chem from caking
LUNAR report
or NUCAN
Location Unit Name Assignment/Air Resources Needed
Name Unit Conditions Actions Needs
CO2 extinguisher: Class Agent Range Duration Sweep Method Amount Service By
Inspection
10BC Carbon Dioxide 8ft 10 seconds slow sweep from edge inward smothers the fire 15lbs of CO2, 34lbs 14oz total weight Service by station 1C
Inspect the tag and pin. Weigh the extinguisher to ensure its within 90% of full weight.
Water extinguisher: Class Agent Range Duration Sweep Method Amount Service By
Inspection
2A water extinguisher Water 40ft 60 seconds side-to-side base of fire cooling 2.5 gallons Serviced by FFs
Inspect by shaking the can to ensure fullness and checking the pressure gauge for proper pressure.
How should extinguishers be mounted
Extinguishers with a weight less than 40lbs shall be mounted with the top not more than 5ft above the floor.
Extinguishers with a weight greater than 40lbs shall be mounted with the top not more than 3½ ft above the floor.
*The clearance between the base of the extinguisher and the floor shall always be at least 4 inches.
Extinguishers should be located along an exit path, by an exit door. Signs must be installed if the extinguisher is not obviously mounted along an exit path.
Extinguisher general inspection
Extinguishers should be inspected weekly. (General inspection) All extinguishers should be cleaned with a damp cloth. Check the nozzles for obstructions, check the hoses and connections for damage, and check the cylinder for damage. Verify inspection date. Check pin and tag.