Static Wicks: \_\_ per wingtip \_\_ per outboard elevator \_\_ on tail/rudder \_\_ on each MLG
2 per wingtip
2 per outboard elevator
3 on tail/rudder
1 on each MLG
Aileron-Rudder Interconnect
Flaps 40 = rudder is __ degrees L/R of center
-Auto when flaps down and turning (older planes)
Flaps 40 = rudder 7 degrees right of center
Nose wheel Steering:
Limited to +/- __ degrees during T/O and Ldg but w/ differential braking and partial power, can go +/- __ degrees
Tightest turn = ___’ (outer wingtip)
Limited to +/-12 but can go +/-60 with differential and power = 33’6” turn radius
Trim:
___ Operated by ___ or ___ inputs.
__ trim is only operated by the pilot
Electrically operated by manual or autopilot inputs
Aileron trim is only operated by the pilot
Pitch Trim:
Red [STAB TRIM] and “Warning Trim”
- ___” after WOW
- ___” after start
… if trim is unsafe for T/O
- 120” after start
Rudder trim:
___ VDC
3-position switch on front of ___
Will / Will not disengage A/P
28 VDC
Switch on front of PCL
Will NOT disengage A/P
Flap asymmetry/twist:
Flap Airspeed Ops Limits
15:
>15
15: 165 KIAS
>15: 130 KIAS
Pusher Ice Mode:
Sources of \_\_VDC: 1)\_\_ 2)\_\_3)\_\_4)\_\_ Source of \_\_VAC: \_\_ - Provides \_\_ VAC at \_\_ Hz - 1 powered by \_\_ Bus, 2 powered by \_\_ Bus - \_\_\_ which powers system after start
28 VDC by Batt, Gen 1, Gen 2, External
26 VAC by DC inverter
Source of 26 VAC: Inverters
- Provides 115 VAC at 400 Hz
- 1 powered by Batt Bus, 2 powered by Gen 1 Bus Bar
- Alternate which powers system after start
If double gen fail, battery can supply essential electric for
Double gen fail = batt supplies for
20 min <60 amps (40 min)
30 min <50 amps (60 min)
1) Min VDC to start
2) Batt < __ Volts = [LOW VOLT] amber CAWS
3) Over-charge if __ amps
4) Over-volt if >/= __ V
1) 24 VDC min to start
2) Batt <18 V = [LOW VOLT]
3) Over-charged if >60 amps
4) Over-volt if >/= 29.5 V
EPS (Emer Pwr Supply) designed for __ min after loss of main elect and batt. Provides __ V and __ Amp Hr
EPS (Emer Pwr Supply) designed for 30 min after loss of main elect and batt. Provides 24 V and 5 Amp Hr
Starter Gen: __ VDC, directly connected to ___ gearbox; can run whole system; max continuous load of __ amps (__ max for 2 min/hr)
Gen 2: __ VDC, __ driven; MCL of __ amps
Generator Control Unit controls output to __ +/- __ VDC and CAWS
Starter Gen: 28 VDC, directly connected to accessory gearbox; can run whole system; max continuous load of 300 amps (450 max for 2 min/hr)
Gen 2: 28 VDC, belt-driven; MCL of 115 amps
Generator Control Unit controls output to 28 +/- 0.25 VDC and CAWS
Any CB > __ amps is NOT accessible in-flight; most of these are accessed by ____
Any CB > 20 amps is NOT accessible in-flight; most of these are accessed by RCCB (Remote-Controlled Circuit Breaker)
Taxi Light mounted on __; indicates down and locked
LDG Lights mounted on __; indicates down and locked
Wing: illuminates ___
Nav: __ on L wing // __ on R wing // __ on top/aft tail
Strobes on ____
Taxi Light mounted on NLG; indicates down and locked
LDG Lights mounted on MLG; indicates down and locked
Wing: illuminates L wing
Nav: red on L wing // green on R wing // white on top/aft tail
Strobes on each wingtim
Beacon: __(#) of __ (color) rotating located __ and __
Recognition: mounted __ of flap fairings, illuminates acft
Beacon: 2 (#) of red (color) rotating located top and bottom
Recognition: mounted fwd of flap fairings, illuminates acft