What is the supply pressure for natural gas
7” to 14” wc
What is the supply pressure for propane
11” wc
Smallest
If your pressure drop is to great you hat do you need to do
Install a larger line
What unit of measurement are all the tables in
Metric
threaded pipe for natural gas must not be smaller than ———inch diameter unless it’s schedule ————
1/2 diameter
Sched 80
a gas line for additional appliances may be installed connecting within ———-inches of the meter outlet, system or secondary regulator
24 inches
What types of copper are approved for use above ground
K,G,L
factory coated with a pvc resin or extruded polyethylene
True
True
What is the maximum length of a flex connector on a vented appliance
2 feet
What is the maximum length of a flex connector on an un vented appliance
6 feet
True
Labels every 20 ft
T OR f
True
Copper tubing installed in a residential application must have what
yellow bands at 6’ intervals through the entire length
Can you have a gas valve installed on the horizontal finish piping
Yes as long as it’s located within 2 ft of the appliance
Whats the maximum distance a gas valve can be located away from the appliance under what circumstances
50 ft as long as it’s clearly tagged and accessible
What is the preferred piping practice when installing a gas valve for an appliance
Installing it on the drop or riser
True
True
What is the hanger spacing for
1/2”
3/4-1”
1 1/4- 2 1/2”
6
8
10
What is the hanger spacing for tubing
6 ft