When is a fire partition used?
What are the exceptions for fire partition use?
Openings in fire partitions must have a min of _ hour rating except for corridors, which must be protected by a _ minute fire protection assemblies
3/4 hour; 20 minute
What purposes are fire barriers used?
Wall or ceiling finishes between _ and _ thick must be applied directly against noncombustible backing, unless the finish is noncombustible or was tested separate from noncombustible backing
1/28” and 1/4”
What test was used exclusively for interior finishes?
ASTM E84 (IBC also allows finishes other than textiles that pass NFPA 286 and when a Class A finish would be required)
Textile wallcoverings must comply with these 3 conditions
Ceiling textile finishes must meet these requirements-
either ASTM E84 with sprinklers or NFPA 286
Americans with Disabilities Act (ADA)
ADA is based on _
International Code Council (ICC) ICC A117.1 Accessible and Usable Buildings and Facilities
Life Safety Code is made by _
National Fire Protection Association (NFPA)
International building code is made by _
International Code Council (ICC)
IBC consolidates _ codes
Boca national building code (BOCA/NBC), Uniform Building Code (ICBO), Standard Building Code (SBC) by Southern Building Code Conference International (SBCCI)
What merged to form the ICC?
BOCA, ICBO, SBCCI
What is the purpose of the IBC?
Who establishes the National Electric Code (NEC)
NFPA
Adopting and enforcing codes is the power of the _
state
_ approves all standards to avoid duplicates
ANSI
Usually _ tests procedures
Nationally Recognized Testing Lab (NRTL
Listed Label
When a product is complete and total product is tested
Classified Label
Things that were tested for certain uses only
ANSI UL 10B
Standard for Fire Tests of Door Assemblies
ASTM C1396
Standard Specification for Gypsum Board
ASTM E119
Standard Test Methods for Fire Tests of Building Construction and Materials