The Captain’s seat, but not the First Officer’s seat, can be adjusted up and down by an electric actuator.
a) True
b) False
b) False
There is no mechanical means of adjusting the height of the pilot seats.
a) True
b) False
b) False
The rudder pedals can be adjusted fore and aft electrically.
a) True
b) False
a) True
What is the EMB-145 Maximum Structural Takeoff Weight?
a) 40,785 lbs.
b) 42,549 lbs.
c) 48,722 lbs.
d) 49,823 lbs.
d) 49, 823 lbs.
When the Cockpit Direct Vision (DV) Windows (side windows) are not properly locked in the closed position, which of the following indications will be present?
a) Single caution chime
b) Message (MSG) on the EICAS display
c) A yellow pin protruding form the flat plate linkage near opening handle
d) Both A and B
c) A yellow pin protruding form flat plate linkage near opening handle
The Emergency Locater Transmitter (ELT) is located above the toilet.
a) True
b) False
a) True
The lavatory toilet is flushed by a pump with is powered:
a) Electrically
b) Hydraulically
c) Pneumatically
d) Mechanically
a) Electrically
The Waste Service Panel and the Potable Water Service Panel are located on the lower aft ______ side of the airplane.
Right
What are the exterior dimensions (in feet) of the EMB-140 and 145 respectively?
a) 105 x 67 x 23, 98 x 67 x 23
b) 94 x 66 x 22, 98 x 66 x 22
c) 100 x 66 x 22, 97 x 66 x 22
d) 98 x 67 x 22, 96 x 67 x 22
b) 94 x 66 x 22, 98 x 66 x 22
The Galley Service Door is hydraulically operated.
a) True
b) False
b) False
To block the baggage door the handle must be turned
a) Clockwise
b) Counter-clockwise
a) Clockwise
Name the three compartment hatches that share the amber EICAS “ACCESS DOOR OPEN” caution MSG.
Forward Electronics Compartment
Rear Electronic Compartment
Under cockpit access (rigging) hatch
The status of the doors and hatches can be found on the Doors section of the _______ page on the ________.
Takeoff System, MFD
In the event of a landing below -40°C, the airplane may not take off without further maintenance inspection.
a) True
b) False
a) True
The minimum operation temperature for takeoff and lading is __°C and the maximum at -1,000 ft. PA is ___°C
-40°C SAT, 52°C SAT
Vlor is ___ KIAS, Vloe is ____ KIAS and Vle is ____ KIAS
200, 250, 250
Mmo is ____, and Vmo is ___ at and above 10,000 ft. is ___ KIAS
.78M, 320
What is the EMB-145 Maximum Structural Landing Weight?
a) 43,651 lbs.
b) 40,785 lbs.
c) 44,092 lbs.
d) 44,312 lbs.
a) 43,651 lbs.
Va is ___ KIAS.
200
Vfe for flaps 9° is __ KIAS, for flaps 22° is __ KIAS, and for flaps 45° is __ KIAS.
250, 200, 145
The maximum takeoff and landing tailwind component is __ KIAS.
10
The runway slope limitation is a negative __% and a positive __%.
-2, +2
The minimum temperature for (manual) Anti-icing Operation is __°C and maximum is __°C.
-40°C, 10°C
The holding configuration while in icing conditions are Landing Gear ___, Flaps ___°, and a minimum airspeed of ___ KIAS.
Up, 0°, 200 KIAS