What is the four step process of an inspection?
What should you take on inspection?
What advice does RICS Surveying Safely 2019 set out?
1) Responsibilities for members and firms
2) Assessing hazards and risks
3) Workplace health and safety
4) Occupational hygiene and health
5) Visiting premises and sites
6) Fire safety
7) Residential property surveying
8) Procurement and management of contractors
What considerations does the RICS Surveying Safely state that you should have of the immediate area?
When carrying out an external inspection, what should you take note of?
When carrying out an internal inspection, what should you take note of?
What are the four common forms of foundation?
What is the measurement of a brick?
215mm x 102.5mm x 65mm
What is solid wall construction?
The simplest type of wall is constructed in solid brickwork with headers
Different bricklaying patterns incorporating headers to tie together brick layers i.e. Flemish Bond
What is cavity wall construction?
Two layers of brickwork are tied together with metal ties with a cavity that may be filled with insulation – NO headers
Evidence of a cavity tray, air brick or weep holes may be seen
What is a stretcher?
A brick laid horizontally – flat with the long side of the brick exposed to the outer face of the wall
What is a header?
A brick laid flat with the short end of the brick exposed to the outer face of the wall
What would be the institutional specification of a shop?
What is the difference between steel frame and concrete frame buildings?
Steel frames – usually have less columns and a wider span between the columns
Concrete frames – usually have more columns , lower floor to ceiling heights and a shorter span between the columns
*If not aware of construction form, check architect’s drawings or building manual
What is the current institutional specification for Grade A offices?
As defined by the British Council for Offices (BCO):
- Full access raised floors with floor boxes
- Carpeting
- Approximate ceiling height of 2.6m
- Ceiling void of 350mm and a floor void of 150mm
- Suspended ceiling
- LG7 compliant lighting
- Approximate floor loading of 3-5 kN per sq m with an allowance of 1kN per sq m for partitioning
- Air conditioning
- Double glazed windows
- Passenger lifts
- Maximum depth of 12m – 15m to allow for natural light to the office area
- Typical car parking ratios of approx. 1 car space per 200 sq ft for a green field site (depending on LA guidelines)
What are the different types of air conditioning?
VAV (Variable Air Volume) – the HIGHEST capital cost but most flexible
Fan Coil – LOW capital cost and good flexibility, but HIGHER operating and maintenance costs
VRV (Variable Refrigerant Volume) – LOW capital cost but HIGHER operating and maintenance costs
Static Cooling (Chilled beam) – a natural approach to climate control with LOW capital and running costs but less flexible
Mechanical Ventilation – when fresh air is moved around the building
Heat recovery systems
Comfort Cooling – a simple form of air cooling system
Are you aware of any upcoming legislation associated with air conditioning?
R22 refrigerant system will become illegal by January 2015 – no replacement/certain repairs permitted
Existing R22 refrigerant systems will need to be modified to become more environmentally friendly
What is the difference between Category A and Category B fit out?
Category A – to a Grade A specification
Category B - occupier’s fit out
What is the institutional specification of an industrial unit/warehouse?
What is subsidence?
Vertical downward movement of a building foundation caused by loss of support of the site beneath the foundation
Could be as a result of changes in the underlying ground conditions
What is heave?
The expansion of ground beneath part or all of the building – could be caused by tree removal
What is wet rot?
Caused by damp and timber decay – signs include wet and soft timber
What is dry rot?
Caused by fungal attack – signs include fungus, strong smell, white felt/cotton wool type strands, red spores, cracking paintwork, cuboidal cracking, crumbling of dry timber
Can destroy timber and masonry
What are the common defects you would expect to see in a period building? (Residential, office, shop)
Dry rot, wet rot, tile slippage on the roof, death watch beetle, damp penetration at roof and ground floor level, water ingress around door/window openings, structural movement