Structural load bearing steel framing can be fastened together using?
Spec’d screws and tack welds
How can non-loadbearing steel framing be fastened together?
Tack welds, self tappers (wafer screws) and crimping
Drywall or paneling should be installed to the open face of a stud first for what reason?
Keeps the stud from twisting when installing the next panel.
Corners and intersections in steel stud framing can be done more economically utilizing what?
Pass though corners and intersections. 3 studs brought down to 2.
What direction does resilient channel get installed?
At right angles to the studs or joists, and nail flange facing down on walls. Facing up creates waves in finish.
How far through steel studs should fasteners pass through?
Min 3/8” (10 mill)
Alignment of gypsum board joints at openings should be?
300 mm min from corners to prevent cracking.
Screw spacing from edge of gypsum board?
3/8” (10 mm)
Screw bit used in drywalling to stop the screw at the right depth and compress the paper around it for easier finish.
Dimpler bit
When lumber shrinks behind fastened drywall leaving a space between the materials can create what when pressure is put on the wall?
Nail popping
What is Gypsum lath.
Comes in 400 x 1200 mm boards 10 to 12 mm thick and is commonly a base for plaster
Metal lath
What is a plaster ground?
Narrow strips of wood that acts as an edge for screeding (striking off) plaster to the correct thickness. Used to keep applications smooth and level
On a suspended tile ceiling, how many cross Ts are needed compare to amount of tiles?
Same amount of cross Ts as there are tiles.
On a suspended tile ceiling, what must be taken into account for the perimeter tiles?
Should be more then half a tile for the edges.
Who is required to design structures of loadbearing steel stud construction?
A qualified engineer
What gauges of steel are used for loadbearing steel stud components?
Hot-dipped galvanized steel in 20, 18, 16 and 14 gauges
How tight should adjacent gypsum board panels be?
Not required to be tight but cannot exceed 3mm.
Drywall is installed on ceilings before it is installed on walls.
True
What is the correct method for cutting gypsum board for electrical boxes using a spiral saw?
Run the bit counter clockwise around the outside edge of the box
What is the minimum length screw that must be used to attach the metal stud system to a building?
38mm 1 1/2”
What side does the cross T clip into the main T on a suspended ceiling?
Left side and then the other side will clip into it.
How many anchors are required for knock-down steel jamb legs?
4 in total. two compression anchors on top and two base anchors
Order of install for knock-down steel jambs.
Header
Hinge leg
Strike leg
Pull down header and secure
Compression anchors
Adjust