What is the tolerance for the installation of all weep screed, casing, and “J” metal straight & level
No Tolerance
Corners of the weep screed are to be ______ cut and _________ to match the corner aid.
Install weep screed, casing, or “J” metal at all stucco
Termination points
__________ weep screed is to be installed at all shear wall locations.
FHA #9
___________ weep screed is to be installed at all non-shear wall locations.
FHA #7
Install _____” casing around all gable vents and caulk entire perimeter.
3/8”
Install _______” casing at all garage returns walls (plate to stem).
3/8”
Install _______” casing at all exterior door openings, the header piece is to extend 1” past each leg (both sides).
1-3/8”
The stucco TradePartner® is responsible to install ____________ behind any non-accessibletub or shower (SheaHomes is to provide batt insulation).
Insulation
Install grade 60 minute “D” vapor barrier on all homes. The vapor barrier is to be installed with a min. ____” _________ _________ ________ and a min. _____” __________ ________ _________. The first two rows of vapor barrier (from bottom) are to be installed behind the window moist stop material.
Install ___________ at all parapet walls. Install over the entire top of the wall and wrapdown both sides a min. ________”.
Install bituthane at all _________ window locations and ledges ____” or deeper. Thebituthane is installed under the window moist stop, wrapped up all side walls a min.4”, and lapped over the front of the wall a min. of 4”.
Verify that the moist stop, bituthane, and grade “D” vapor barrier are installed tightly in to the corners at all __________ windows and _________ locations.
Install _______”- ________ gauge wire over 1.5 lb. tongue & groove foam board.
Install standard foam tightly utilizing the interlocking ________ & __________.
tongue & groove
Foam is to be installed ______________ with the sheets staggered at the joints.
horizontally
Foam is to be installed tight to the window frames (max. _____” gap).
1/4”
Foam is to be installed tight to the eave blocks (max. ______” gap).
1/4”
Foam is to terminate directly on top of the _____-______ at all mopboard locations.
Z-Bar
All non-tongue & groove joints are to be _______, ____________, or ____________ per the local municipality guidelines.
Taped, caulked, or covered
Install ______” R-tech® foam or equivalent at all attic areas (standard foam is not acceptable at attic areas). All joints are to have solid 2x backing both vertically and horizontally (joints are to be cut at existing backing). All non-tongue & groove seams and gaps that exceed ____” are to be sealed using R-tech® tape or equivalent only (this also includes gaps at barge blocks).
Wire to be installed with a min. ____” horizontal head lap and a min. ____” vertical end lap.
All wire is to be stapled off ____” OC at the perimeter and ______” OC in the field.
The staples should not be set deeper than _____” below the surface of the foam.
3/8”