IR FAULT LIGHT
- STEADY…IR not recoverable
ON BAT LIGHT
IR ALIGN LIGHTS
ADR P/B
- OFF…ADR is disconnected
GEN 1 LINE P/B
RAT/EMERG GEN FAULT LIGHT
MAN ON P/B
TERR P/B
SYS P/B (GPWS)
Mode 1 = Excessive descent rate “Sink Rate”
Mode 2 = Excessive terrain closure “Terrain, Terrain”
Mode 3 = Altitude loss after T/O “Don’t Sink”
Mode 4 = Unsafe terrain clearance “Too Low Flaps”
Mode 5 = Excessive GS deviation “Glideslope”
G/S MODE P/B
FLAP MODE P/B
LDG FLAP 3 P/B
- Mode 4 = Unsafe Terrain Clearance…..”Too Low Flaps”
RCDR GND CTL P/B
CVR ERASE
-PRESSED FOR 2 SECS-
-Erases tape:
…. On ground w/Parking Brake on
MASK MAN ON P/B
-AUTO…Masks deploy when cabin alt > 14000 ft, a pre-recorded msg plays in cabin
…chemical generators supply oxy for 15 mins
-MASK MAN ON…Manually deploys PAX O2 masks- no pre-recorded msg
PASSENGER
-SYS ON…Illuminates when control of O2 mask doors is actuated until the OXYGEN TMR RESET P/B on the MX panel is activated
CREW SUPPLY
- OFF…valve closed
CALLS: EMER
ENG FIRE P/B
-ILLUMINATED…Dual gas loops in Pylon Nacelle, Fan & Core. Losing both loops within 5 secs = Fire Warning
APU FIRE P/B
-ILLUMINATED…Dual gas loops in APU compartment, on ground auto shutdown & discharge of fire bottle in 3 secs (ext. Horn)
AGENT P/B
-SQUIB…Corresponding FIRE P/B must be pushed to arm
…Pressed = Bottle discharges, #1 starts 30 sec timer on ECAM
-DISCH…Bottle is depressurized
FIRE TEST P/B
-PRESS…Tests respective fire detection & extinguishing systems
-ENG (7 lights): FIRE P/B -APU (5lights): FIRE P/B
2 SQUIB/DISCH SQUIB/DISCH
2 Master warn 2 Master warn
ECAM ECAM
Fire lt pedestal
RAT MAN ON P/B
-Extends RAT providing 2500psi Blue Hyd, Emergency Gen not powered
PTU P/B
-AUTO…Runs @500 psi differential, self test during 2nd eng start
…Inhibit Logic: 1. First ENG start
2. Cargo door operation/40 secs after
3. Parking brake On w/one ENG MASTER ON
4. Parking brake OFF w/one ENG MASTER ON
& NWS deactivation pin installed
-OFF…Deactivated, extinguishes FAULT lt (unless overheat)
-FAULT (Green/Yellow): 1. Low quantity
2. Reservoir overheat
3. Reservoir low air pressure