What is the intent of the Material Concept?
Limit lead on Newly installed fire alarms, meters, sensors, relays, thermostats and load break switches?
2. Products contain no more than 0.01% (100 ppm) of lead by weight.
Limit lead in paint?
Limit lead in Drinking water pipes, fittings and solder
a. The product is approved for use with drinking water by a local government authority or by a governmentauthorized certification body.
b. The product has a weighted wetted average of 0.25% of lead or less, verified by a third party, or is labeled as
ANSI/NSF 372-compliant.
Limit Mercury in Newly installed fluorescent
3.5mg to 10mg
Limit Mercury in Newly installed Sodium lamps
Limit Mercury in Newly installed fire alarms, meters, sensors, relays, thermostats and load break switches
2. Products contain no more than 0.1% (1000 ppm) of mercury by weight
.List of product categories do not contain over 1,000 ppm of asbestos by weight?
How many death asbestos exposure causes every year?
200,000 deaths annually
What hazardous material is banned worldwide?
PCB
What does asbestos exposure causes in the body?
Mesothelioma
What does ingested, absorbed or breathed lead in the body?
t accumulates in blood, tissues and bones, potentially disrupting body functions and mpairing the intellectual development of children and the unborn during pregnancy
How to manage asbestos?
2. Confirmation with PLM or TEM testing. . Materials having over 1% of asbestos are considered ACM
: Asbestos action plan
a. Notification of any works to relevant authorities and persons living, working or transiting in the vicinity of the building or space.
b. Preventative measures against the formation and spread of asbestos fibers in the air during remedial work.
c. Measures taken for workers’ protection during remediation activities, including but not limited to skin and respiratory protection.
d. If ACM are being removed, activities are carried out for proper handling of ACM waste, including: wetting of all removed ACM, care in transportation to prevent crumbling, sealing and leak-tight transportation, proper labeling and final disposal in locations allowed by applicable laws and permits.
e. Post-remediation clearance for occupancy confirmation by testing of fibers in air using phase contrast
f. If any of the asbestos is managed by methods other than removal, the month and year of follow-up inspection to evaluate the structural integrity of the ACM must be stated and cannot exceed three years from the date of the last inspection.
Manage Lead Paint Hazards
Manage Polychlorinated Biphenyl (PCB) Hazards
PCB action plan
What are the preconditions of the concept MATERIALS?
X01 MATERIAL RESTRICTIONS
X02 INTERIOR HAZARDOUS MATERIALS MANAGEMENT
X03 CCA AND LEAD MANAGEMENT
What are the optimizations of the concept MATERIALS?
X04 SITE REMEDIATION X05 ENHANCED MATERIAL RESTRICTIONS X06 VOC RESTRICTIONS X07 MATERIALS TRANSPARENCY X08 MATERIALS OPTIMIZATION X09 WASTE MANAGEMENT X10 PEST MANAGEMENT AND PESTICIDE USE X11 CLEANING PRODUCTS AND PROTOCOLS X12 Β CONTACT REDUCTION
When CCA was banned?
2000
Where CCA was used?
Pressure treated wood
What are the health issues of arsenic exposure?
increased risk of skin, liver, bladder and lung cancers
How to identify CCA-containing wood?
How to address CCA-containing woods?