Set the following gear up pitch attitude and thrust: - Flaps extended…10 deg and 80% N1 - Flaps up…4 deg and 80% N1
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q
Dual Engine Failure
Condition: One of these occurs on both engines:
Engine flameout
No response to thrust lever movement
A
ENG START selectors (both)…FLT
Thrust levers (both)…Idle ————————————-
FUEL CONTROL switches (both)…CUTOFF, then RUN