Aborted Engine Start L,
[] ENG AUTOSTART L, R
FUEL CONTROL switch (affected side) . . . . . . . . . . . . . . . . . . . CUTOFF
[] AIRSPEED UNRELIABLE
Flaps extended . . . . . . . . . . 10° and 85% N1
Flaps up . . . . . . . . . . . . . . . . 4° and 70% N1
[] CABIN ALTITUDE
PASS OXYGEN switch . . . . . . . Push to ON and hold for 1 second
Without delay, descend to the lowest safe altitude or 10,000 feet, whichever is higher.
To descend:
Dual Eng Fail/Stall
[] ENG LIMIT EXCEED L, R
[] ENG SURGE L, R
Eng Svr Damage/Sep L, R
[] FIRE ENG L, R
If the FIRE ENG message stays shown:
Engine fire switch (affected side) . . . . . . . . . . Rotate to the stop and hold for 1 second
Engine fire switch (affected side) . . . . . . . . . .Rotate to the other stop and hold for 1 second
[] STABILIZER