which two sections of ibc should one reference to determine the need for fire separation between occupancies?
what is the maximum height of a service counter?
36”
what is the maximum height for a typical ada counter?
34”
what is the max accessible height to the reflective surface of a mirror?
40”
where should occupant sensors (to control lights) be placed?
what is the range of accessible heights for dining / work surfaces?
28” - 34”
are afci or gfci outlets required in residential kitchens?
gfci
built-in microwaves require which type of outlet?
duplex
outlets at countertops must be placed within how many inches above the countertop?
20”
appliances requiring heat need an outlet of what voltage?
240V
no more than __________” between outlets at a countertop / work surface?
24”
what is the clear floor space needed in front of a lavatory?
30” x 48”
what is the clear floor space needed around a toilet?
56” x 60”
if one is given an occupant load for a space, how should one calculate plumbing fixture counts?
usb receptacles to not require afci unless…
they are paired with an outlet of a normal amperage
where shall smoke detectors be placed?
where are residential smoke / heat detectors required to be placed?
wall outlets shall be mounted how far apart, horizontally?
6’-0”
what is the accessible mounting height of a wall outlet?
15” min, to the bottom of the outlet
what is the accessible mounting height of a wall switch?
15” - 48”, to the centerline of the switch
what is the maximum placement of a sprinkler head from a wall?
7’-6”
what is the maximum spacing between sprinkler heads?
15’-0”
what is the furthest horizontal dimension a supply pipe can be from a plumbing trench?
10’-0” maximum
what is the reach range for side and front approaches?
15” - 48”