Initial Steps of Resuscitation
Flow inflating bag
▪Can deliver a 100% if needed ▪Easy to determine if there is a seal ▪Stiffness of the lungs can be felt ▪Can deliver O2 via blow-by ▪Requires a tight seal ▪Requires a gas source ▪Not all flow-inflating bags have a pop- off
How to provide flow by
Do not use Self inflating bag
Sp02 preductal target ranges
1 min - 60-65% 2 min - 65-70% 3 min - 70-75% 4 min - 75-80% 5 min - 80-85% 10 min - 85-95%
ETT size based on age/gestation
Fi02
- O2 is necessary start at 30% using a blender
BVM
▪Will always refill, even without a gas source ▪Has pressure relief pop-off valve (pre-set 40 cwp). ▪Not as easy to determine if you have a good seal ▪Requires a reservoir to deliver ~100% ▪Cannot deliver blow-by O2
T-piece
▪S/U with blender
▪Start with room air and
increase O2 when indicated
by SpO2
Steps to PPV
▪Clear Airway ▪Position yourself at HOB ▪Position baby’s head and neck ▪Neural or sniffing position ▪Properly position mask to face ▪Two shapes – round or anatomically shaped ▪One or two hand techniques