What color do gram positive microorganisms stain?
Blue or Purple
Where should the chemical indicator be placed in a wrapped set of instruments?
The Center of the Set
Medical grade paper is NOT used in which type of sterilization
Low Temp hydrogen peroxide gas plasma sterilization
If a technician’s skin is exposed to liquid ethylene oxide, what should the technician do first?
Wash the exposed area with large amounts of soap and water
The EPA, FDA, OSHA, and State Health Departments issue regulations
True
Hair coverings are required
In all areas of the department
Establishes sterile practice based on opinion, research and theory
AAMI (The Association for the Advancement of Medical Instrumentation)
Which of the following agencies would approve the disinfectants used on floors and walls in the sterile processing department?
EPA (The Environmental Protection Agency
According to OSHA, what means are used to inactivate blood borne pathogens?
Disinfection, Decontamination
A staff member brings several contaminated trays to the sterile processing department on a cart and requests that replacement trays be put on the same cart. The technician should?
Clean and dry the transport cart and send it to distribution for the trays
Patient care equipment?
Is considered non critical (equipment that contacts intact skin should be cleaned and undergo low-to-intermediate-level disinfection
Which of the following generally describes the correct sequence for the traffic workflow in areas in which medical devices are processed?
Decontamination, Assembly, Packaging, Sterilization, Sterile Storage
A Type 5 indicator is called a(an)?
Integrating Indicator (reacts to all critical variables of the sterilization process and provides a level of assurance that the sterilization conditions have been met throughout the cycle)
A solution with a pH of 3 is considered
Acidic (lower numbers indicate higher acidity; 7 is neutral; above 7 is alkaline
Simultaneous wrapping means to wrap an instrument set with?
A single woven wrapper, double-ply, bonded at the edges.
A liver biopsy would be performed to check for which disease?
Hepatitis C Virus
Which of the following should be used to write on instrument count sheets and tray lists?
Permanent nontoxic ink markers
Items being unloaded from the steam sterilizer should be handled with
Clean hands (or appropriate protective gloves)
The effectiveness of any chemical disinfection process depends on all the following except
Cost of chemical
EPA, FDA, OSHA, and DOT issue
Regulations
What information does a technician need to properly clean a new medical device?
Manufacturer’s instructions for use
Which of the following chemical indicators should only be used in the specific cycle for which they are labeled?
Emulating (Class 6 chemical indicators, aka, emulating indicators, should only be used in the specific cycle for which they are labeled.
Single use devices that are reprocessed must be cleared by the FDA
TRUE
Clean to dirty is a sterile processing department term used to describe?
Workflow