Observer Oxygen Mask Test
Audio control panel…………Set
Oxygen panel……..Set
Flight Deck Access System Test
*With the flight deck door open:
-FLIGHT DECK DOOR rotary switch……AUTO
-Access code…….Enter
-ENT key……..Push
—Verify alert sounds.
—Verify amber keypad LED illuminates.
—Verify AUTO UNLK light illuminates.
Flight Recorder
GPWS/Windshear
Transponder/TCAS
Window Heat System Tests- Overheat Test
Overheat Test
*WINDOW HEAT switches………..ON
*WINDOW HEAT TEST switch………..OVHT
-OVERHEAT lights – On
-ON lights – Extinguish
Lights extinguish after approximately 1 minute.
Window Heat System Tests- Power Test
Total Air Temperature (TAT) Test
Cockpit Voice Recorder Test
*TEST switch………….Push
Fire and Overheat System Test
*Fault/Inop detection…………….Check
-OVERHEAT DETECTOR switches - NORMAL
-TEST switch - Hold to FAULT/INOP
Verify MASTER CAUTION, OVHT/DET annunciator, FAULT and APU DET INOP lights are illuminated.
—If the FAULT light fails to illuminate, the fault monitoring system is inoperative.
—If APU DET INOP light fails to illuminate, do not operate APU.
*Fire/Overheat warning…………….Check
-TEST switch - Hold to OVHT/FIRE
—Verify fire warning bell sounds, master FIRE WARN lights, MASTER CAUTION lights and OVHT/DET
annunciator illuminate.
*Master FIRE WARNING light - Push
-Verify that the engine No. 1 and engine No. 2 start lever lights stay illuminated.
-Verify master FIRE WARN lights and fire warning bell cancel.
-Verify engine No. 1, APU, and engine No. 2 fire warning switch and engine No. 1 and engine No. 2 OVERHEAT lights are illuminated. If AC busses are powered, verify WHEEL WELL fire warning light is illuminated.
If an engine fire warning switch and an ENG OVERHEAT light do not illuminate, a detection loop is inoperative.
Cargo Fire Protection System Test
Weather Radar Test
If testing of the PWS system is desired: