Factors that impact the selection of a frequency for an EC inspection: (4)
Frequency formula (plate)
F = 1.6p/t²
F = frequency (KHz) p = plate resistivity (ohm) t = plate thickness (mm)
Frequency formula (tube)
F90 = 3p/t²
F90 = frequency (KHz) p = tube resistivity (ohm) t = tube wall thickness (mm)