GTMI: What is maximum temperature for entering module?
140 degrees
GTMI: What must be done prior to entering module
GTMI: If entering module less than 2 hours after shutdown, what PPE is required?
Flame retardant gloves
GTMI: What PPE is required for running GTMI
GTMI: How long must module cooling fans be run prior to entering module?
5 minutes
GTMI: Prior to entering module..a, b, c, d
A) GT SD or idle
B) HFP Deactivated
C) Safety Observer stationed at doors
D) Module CLG Fan M/C is in disabled position
GTMI: If immediate entry is required after normal or e-stop…a, b, c, d
A) Module CLG Fan off
B) Both doors open
C) Vent damper open
D) Module CLG Fan operated as needed
CPP: Low Sump Alarm
225 Gallons
CPP: Normal Sump Level
350 Gallons
CPP: High sump level
425 Gallons
CPP: High Temp Alarm
160 deg
CPP: Low Temp Alarm
80 deg
Shafting: How many LSB on starboard shaft?
Location?
Shafting: How many SW lubricated bearings per shaft?
-3
Shafting: How many shaft segments on starboard shaft?
7
MCS: What color are EOT Alarms?
Sound?
White
Pulsed Bell 4X
MCS: What color are Level 1 Alarms?
Usage?
Sound?
MCS: What color are level 2 alarms?
Usage?
Sound?
MCS: What color are level 3 alarms?
Usage?
Sound?
MCS: What color are BIT alarms?
Sound?
Shafting: What is the length of the starboard shaft?
224’ 2-37/64”
MRG: Classify MRG
GT: What compressor stages provide bleed air?
GT: What does 9th Stage Bleed Air provide?