What is the lowest pressure the engine can pump off of?
5 PSI
1 3/4” numbers
125 PSI
250 ft.
15 psi per 50ft. (75 psi total)
50 psi at the nozzle
2 1/2” numbers
90 psi
250 ft.
15 psi per. 100ft. (37.5 psi total, round to 40)
50 psi at the nozzle
High rise numbers
120 psi
150ft. 1 3/4” 45 psi
Stand pipe 25 psi
50 psi at the nozzle
10 psi for every 100’ 3” in the road
5 psi per floor
High rise (laying lines)
Pump engaged
20,10,7 rule
After opening the first attack line of the pressure drops
20% you can pump 1 line of equal or less
10% 2 lines of equal or less
7% 3 lines of equal or less
Deck gun
80 psi nozzle
15 psi appliance
5 psi elevation
Air bound
If there is a issue with hydrant pressure
Black widow tip (Truck 1)
2 1/2” | 100ft. | 60 psi
3” | 100 ft. | 30 psi
Nozzle 100 psi
GPM 700
Truck 1 How Ya Doin
150 psi don’t exceed 200 psi
1-2 lines for one stream
3-4 lines for 2 streams
Brensan Distributor
2 1/2” | 100 ft. | 15 psi
3” | 100 ft. | 6 psi
Nozzle 50 psi
GPM 250
Why and when do we close the tank to pump at engine 4?
Hose bed
Supply lines:
-28 3” lengths total (1400 ft.)
-50 ft. Per length
-14 lengths each primary and secondary (700 ft. each)
Attack lines:
-Primary attack line 1 3/4” 250 ft. 5 lengths (smooth bore)
-Secondary attack line 1 3/4” 250ft. 5 lengths (fog nozzle)
-2 1/2” 250 ft. 5 lengths (smooth bore)
Forward lay (Hydrant to fire or dragging back)
Reverse parallel lines (fire to hydrant or reversing out)
Reverse hook up big (reversing out or fire to hydrant)
2” Red
2 1/2” @ 100 ft. 160 psi
3” @ 100 ft. 80
80 psi NP
1000 GPM
1 3/4” yellow
2 1/2” @ 100 ft. 100 psi
3” @ 100 ft. 50
80 psi NP
800 GPM
1 1/2” green
2 1/2” @ 100 ft. 60 psi
3” @ 100 ft. 30
80 psi NP
600 GPM
1 3/8” white?
2 1/2” @ 100 ft. 40 psi
3” @ 100 ft. 20
80 psi NP
500 GPM
Akon smooth bore 7/8
30 psi per 100 ft.
50 psi NP
160 GPM
Elkhart Fixed Gallonage Fog Nozzle
1 3/4
30 per 100 ft.
50 psi NP
150 GPM