(Volume flow rate)
V.
V. = A • V
where: A = π/4(D^2) cross sectional
are
V = Velocity of flow
TDH = Vd²/2g
Total Dynamic Head (TDH)
Hs + Hp + Hv + Hf
Pressure Head (Hp)
( Pd - Ps / Y )
Where Y: Unit weight water= 9810N/m^3
Velocity Head (Hv)
Vd^2 - Vs^2 / 2g
Friction Head (Hf)
FlV^2/2gD
Where: F = Friction coefficient
D = Pipe Diameter
L = Length of pipe
Water Power/ Hydraulic (WP)
WP = Y V. TDH
Pump Efficiency (ep)
WP/BP
Motor Efficiency (em)
BP/IP
Overall efficiency (eo)
WP/IP