QUIZLET Flashcards

(369 cards)

1
Q

WHAT IS THE NAME OF A MATERIAL THAT CAN CARRY AN ELECTRICAL CHARGE FROM ONE POINT TO ANOTHER?

A

ELECTRICAL CONDUCTOR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

WHAT IS USED AS A REFERENCE VALUE OF 100% CONDUCTIVITY?

A

ANNEALED COPPER

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

WHAT PROCESS HAS ANY ADVERSE EFFECT ON CONDUCTIVITY OF PURE COPPER?

A

ALLOYING COPPER

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

ADVANTAGE OF SOLID CONDUCTOR?

A

BETTER TRANSMISSION

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

ADVANTAGE OF STRANDED CONDUCTOR?

A

*MORE FLEXIBLE
*LONGER LIFE
*LESS SUSCEPTIBLE TO DAMAGE DURING CRIMPING

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

WHAT IS AWG?

A

AMERICAN WIRE GAUGE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

WHERE IS AWG ACCEPTED ?

A

WORLD WIDE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

WHERE WILL PVC AND PE CABLE BE USED ?

A

*PVC IS USED INDOORS
*PE IS USED OUTSIDE FOR OSP CABLE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

TEFLON IS TRADE MARK OF ____?

A

DUPONT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What direction is twisted parrot cable twisted and what twist rate

A

Counterclockwise at 1/2 rate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

At what temperature would attenuation increase in copper cabling?

A

68°

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Where will higher temperature be routinely encountered?

A

Inside building walls, ceiling, space, and mechanical rooms

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What is the proper name of a solid wall metal tube and what is it used for?

A

Conduit and best possible shield

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Drain wires are usually?

A

Applied longitudinally

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

AN analog signal is in the form of_____?

A

Wave

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What is the most fundamental example of an analog signal?

A

SINUSOID

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

What is the frequency range of human hearing?

A

20HZ-20KHZ

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

What is the frequency range of voice circuits?

A

300-3400 HZ

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

What is the value of 1KHZ?

A

1000 HZ

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

WHOSE THEORY IS THE SINUSSOID SIGNAL

A

JOSEPH FOURIER

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

What is the speed of light?

A

186000 MILES PER SECOND

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

What is the symbol that represents the speed of light?

A

C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

What is the speed of light within a cable?

A

.5C to .74C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

What is the minimum cable standard for telephony performance?

A

CAT5E AND CAT6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
What do you call a digital signal change from one state to another?
DISCRETE STEPS
26
WHAT TYPE OF TELECOMMUNICATION SYSTEM TYPICALLY COMBINES BINARY DATA FROM SEVERAL DIFFERENT SOURCES INTO A SIGNAL COMPOSITE BITSTREAM( COMBINES MANY SOURCES INTO 1 BITSTREAM SIGNAL)?
TIME DIVISION MULTIPLEXING ( TMD )
27
THE TERM BAUD IS USED WHEN DISCUSSING WHAT?
MODEMS
28
WHAT IS A TERM USED TO DESCRIBE THE TRANSMISSION OF SIGNALS IN ONE DIRECTION ONLY ? ONE DIRECTION AT A TIME
HALF DUPLEX
29
WHAT IS A TERM USED TO DESCRIBE THE TRANSMISSION OF SIGNALS IN ONE DIRECTION ONLY ? BOTH DIRECTION AT THE SAME TIME ?
FULL DUPLEX
30
WHAT IS A TERM USED TO DESCRIBE THE TRANSMISSION OF SIGNALS IN ONE DIRECTION ONLY ?
SIMPLEX
31
What type of circuit connects three information channels, high-speed downstream channel medium speed, duplex channel, and pots channel?
ADSL CIRCUIT
32
What is signal interference between cable Pairs , which may caused by picking up unwanted signals from other pairs or nearby cables? 
CROSSTALK
33
What is the maximum allowance length of data link?
295 feet ( 90 M )
34
What is the maximum allowance length of a patch of cable at the end of a link?
16 Feet ( 5M )
35
How do you define a cable channel?
A channel is a compromised of a link cable and the patch cables?
36
WHAT IS A DATA LINK CABLE?
HORIZONTAL CABLE ( CABLE BETWEEN DATA JACK AND PATCH PANEL)
37
WHAT IS THE MAXIMUM RECOMMENDED LENGTH OF A CHANNEL?
328 ft ( 100 m )
38
WHAT IS THE FREQUENCY OF CAT3?
16 MHZ
39
WHAT IS THE FREQUENCY OF CAT5?
100 MHZ
40
WHAT IS THE FREQUENCY OF CAT5e?
100 MHZ or 350 MHZ
41
WHAT IS AN IMPEDANCE MATCHING DEVICE ? THIS DEVICE IS REQUIRED WHENEVER A TRANSITION IS MADE FROM ?
BALUN TO TRANSITION TWISTED PAIR( COPPER) TO COAX
42
WHAT ARE TWO TRANSITION MEDIUMS MOST OFTEN ENCOUNTERED IN TELECOMMUNICATION CABLING ?
COPPER & FIBER
43
WHAT ARE THREE MAJOR TYPE OF LIGHT SOURCES ?
*LEDS *SHORT WAVELENGTH LASERS *BANDWIDTH REQUIRED
44
WHAT DOES THE DESIGNER HAVE TO CONSIDER WHEN DECIDING WHAT CORE SIZE FIBER TO USE?
*ACTIVE EQUIPMENT *DISTANCE SIGNAL IS TRAVELING *BANDWIDTH REQUIRED
45
WHAT LIGHT SOURCE ARE TYPICALLY ASSOCIATED WITH MULTIMODE OPTICAL FIBER ?
LEDS & VCSEL
46
FIBER MICRON OM1?
62.5 MICRON MULTIMODE
47
FIBER MICRON OM2
50 MICRON MULTIMODE
48
FIBER MICRON OM3
50 MICRON MULTIMODE, LASER ,2000MHZ BANDWIDTH
49
FIBER MICRON OM4
50 MICRON MULTIMODE, LASER ,4700MHZ BANDWIDTH
50
WHAT FIBER CLASS UTILIZE A LASER LIGHTSOURCE AND HAS 2000MHZ BANDWIDTH?
OM3
51
WHAT FIBER CLASS USED FOR DATA CENTER?
OM4
52
WHAT FIBER CLASS DESIGNED FOR LOW WATER PEAK?
OS2
53
WHAT IS DISPERSION?
Light loss
54
THE MAXIMUM OPTICAL FIBER DISPERSION IS USUALLY EXPRESS IN?
PICOSECONDS
55
THE CHROMATIC AND MODAL LIGHT LOSS DISPERSION CHARACTERISTICS ARE ASSOCIATED WITH WHAT TYPE OF FIBER ?
MULTIMODE
56
THE TWO MAJOR CLASSIFICATIONS OF OPTICAL FIBER ARE WHAT?
MULTIMODE SINGLEMODE
57
WHAT ARE WAVELENGTHS AREAS THAT ARE MOST SUITABLE FOR OPTICAL COMMUNICATION?
WINDOWS
58
WHAT ARE TWO FREQUENCY RANGE OF MULTIMODE FIBER ?
MULTIMODE 850 NM & 1300 NM
59
WHAT ARE TWO FREQUENCY RANGE OF SINGLEMODE FIBER ?
SINGLEMODE 1310 NM & 1550 NM
60
WHAT DOES OTDR MEAN ?
OPTICAL TIME DELAY REFLECTOMETER
61
WHAT DOES OTDR DO?
TROUBLESHOOTS FIBER
62
WHAT DEVICE DO YOU USE FOR OTDR?
POWER METTER
63
THE BANDWIDTH FOR AN OPTICAL FIBER CAN ONLY BE VERIFIED?
CAN ONLY BE DONE BY THE MANUFACTURER NOT IN THE FIELD
64
RUNNING FIBER FROM BUILDING A TO BUILDING B HAS A TOTAL FIBER LOSS OF _______?
4.35 DB
65
WHAT IS THIS CALLED ?
LINK LOSS BUDGET
66
HOW MUCH DB LOSS FOR LASER TRANSMITTER ?
3 DB
67
WHAT IS THE SIGNAL LOSS FOR FIBER CONNECTION?
.75 DB
68
HOW MUCH DB LOSS FOR LED TRANSMITTER?
2 DB
69
WHAT IS THE CONNECTION LOSS FOR FIBER SPLICE?
0.3DB
70
WHAT ARE TWO TYPES OF SPLICES ?
FUSION SPLICE( PERMANENT ) MECHANICAL SPLICE (FOR EMERGENCY)
71
HOW MANY SPLICES SHOULD THE DESIGNER ALLOW FOR IN THEIR REPAIR MARGIN?
NO MORE THAN TWO SPLICES
72
WHAT IS THE DATA RATE OF AN OCI CONNECTION ?
51.84 MB/SECOND
73
HOW MANY VOICE CHANNELS ARE THERE IN AN OC12 CONNECTION?
8064 CHANNELS
74
HOW MANY CHANNELS ARE IN DS1?
24 CHANNELS
75
HOW MANY CHANNELS ARE IN DS2?
96 CHANNELS
76
HOW MANY CHANNELS ARE IN DS3?
672 CHANNELS
77
WHERE IS VISIBLE LIGHT ON THE ELECTROMAGNETIC SPECTRUM ?
10 to the 15th POWER ( AKA 10 PETAHERTZ )
78
WHAT IS THE FREQUENCY OF A VISIBLE LIGHT?
1 PETAHERTZ
79
HOW DOES INTERFERENCE GET INSIDE OF EQUIPMENT?
INPUT SIGNALS LINES OUTPUT SIGNAL LINES POWER CORDS ( OR POWER INPUTS)
80
WHAT IS TE?
TELECOMMUNICATION ENCLOSURE ( A CASE )
81
A TE SERVES WHAT SIZE AREA?
3600 SQFT OR 36 work areas ( 1 WORK AREA= 100 SQFT)
82
WHAT IS A TR?
TELECOMMUNICATION ROOM ARCHITECTURAL SPACE ( PASSIVE SPACE )
83
WHAT IS A ER ?
EQUIPMENT ROOM (ENVIRONMENTALLY CONTROLLED)
84
WHERE DOES THE OSP UTILITY COME INTO THE BUILDING?
EF ( ENTRANCE FACILITY )
85
MINIMUM CEILING HEIGHT FOR TELECOMMUNICATION SPACE ?
8 feet
86
RECOMMENDED CEILING HEIGHT FOR TELECOMMUNICATION SPACE ?
10 feet
87
TYPICAL CLEARNANCE
3.28 feet
88
THE MINIMUM OF DEPTH OF EQUIPMENT OFF OF THE WALL IS ____?
6 inches
89
WHAT’S THE AMOUNT OF SIDE CLEARANCES IS REQUIRED FROM THE EQUIPMENT TO THE CORNERS ?
12 inches
90
SIZE OF THE CONDUIT AND SLEEVES USED FOR BACKBONE PATHWAYS FOR TR / ER / EF ?
(4) 4” CONDUITS
91
SIZE OF THE CONDUIT AND SLEEVES USED FOR BACKBONE PATHWAYS FOR TE / ?
(2) 4” CONDUITS
92
WHAT IS THE DOOR SIZE DOR TELECOMMUNICATION SPACES?
3 FOOT
93
TR EQUIPMENT POWER
(2) DEDICATED TWIST LOCK POWER OUTLETS ABOVE EACH RACK
94
TR CONVENIENCE OUTLETS
6” AFF, EVERY 6FEET AROUND PERIMETER OF THE ROOM
95
TELECOMMUNICATION SPACE SHALL BE EQUIPPED TO PROVIDE __________?
DEDICATED ELECTRICAL PANEL MINIMUM DEDICATED (2) NON-SWITCHED EQUIPMENT OUTLETS
96
HOW DOES THE DESIGNER DEPLOY THE TEMPERATURE AND THE HUMIDITY OF THE HVAC SYSTEM?
FOLLOWING THE MANUFACTURER GUIDELINES
97
COORDINATING THE TR LIGHTING LAYOUT WITH WHAT ___________?
EQUIPMENT LAYTOUT
98
DESIGNER SHOULD PROVIDE MINIMUM LIGHTING OF ____________?
500 LUX OR 46 FOOTCANDLE LIGHTS
99
IF YOU ARE SERVING AN AREA OF 5000 SQFT OR LESS THE TR ROOM SHOULD BE?
10x8 TELECOMMUNICATION ROOM
100
IF YOU ARE SERVING AN AREA BETWEEN 5000 SQFT AND 8000 SQFT , THE TR ROOM SHOULD BE?
10x9 TELECOMMUNICATION ROOM
101
WHAT SPACE DO YOU NEED FOR BALANCED TWISTED PAIR CABLE ?
4 SQUARE INCHES ( HOOK 4 PAIRS FOR 4 INCHES)
102
WHAT SPACE DO YOU NEED FOR A STRAND OF OPTICAL FIBER
2 SQUARE INCHES PER STRAND
103
IF 144 STRANDS OF FIBER ARE ENTERING A TELECOM ROOM,HOW MANY SQUARE INCHES OF SPACE SHOULD BE PROVIDED FOR TERMINATION SPACE
288 SQUARE INCHES
104
The racial of 1RU patch panel to cable managers is_______?
1RU HORIZONTAL CABLE MANAGER PER 1RU PATCH PANEL PLUS 1 ADDITIONAL 1RU CABLE MANAGER
105
A telecommunication space should have what fire rating?
2 HR RATING
106
What height should plywood be mounted to prevent damage in an event of flooding or moisture on the floor?
8” AFF
107
Plywood grade shall be shown_______?
PLYWOOD SHALL BE GRADE A WITH STAMP FACING OUTWARD
108
PLYWOOD SHOULD BE PAINTED ___________?
WITH 2 COATS OF FIRE RETARDANT PAINT ON ALL SIDES ( LIGHT COLOR)
109
DIFFERENCE BETWEEN TR/TE AND ER/EF
TR/TE ARE TENANT/FLOOR SERVING NOT BUILDING OR CAMPUS SERVING ER/EF SERVE LOCAL TENANT OR FLOORS AND /OR BUILDING/CAMPUS
110
AT LEAST HOW MANY TR/ER PER FLOOR ?
ONE TR OR ER
111
WHAT ARE THE TYPICAL MINIMUM DIMENSIONS OF A TELECOMMUNICATION ROOM?
8x10 feet
112
TE SHALL SERVE AN AREA___________?
MAX 3600 SQFT ( 36 WORK AREAS ) ( 1 WORK AREA= 100SQFT )
113
IF YOUR TR IS UNDERNEATH OF AN RESTROOM OR NEXT TO A WELDING SHOP AND THE OTHER SIDE OF IT IS A CAFETERIA. WHAT ACTION SHALL YOU TAKE ?
RELOCATE TE( TO AVOID AREA OF HEAT AND OVERHEAD EXPOSURE TO WAYER
114
CALCULATE THE NUMBER OF WORK AREAS?
1 WORK AREA= 100 SQFT
115
HOW WOULD YOU CALCULATE THE NUMBER OF BAS DEVICES TO BE SERVED BY AN ER?
DIVIDE TOTAL AREA BY 250SQFT
116
(RCDD QUESTION) Calculate TR ?
205 Sqft
117
TR SPACE REQUIRED WORK AREA
1 WORK AREA= .75 SQFT
118
ER SPACE REQUIRED BAS DEVICE ?
1 BAS DEVICES= .25 SQFT
119
WHEN LAYING OUT CABLE PATHWAYS TO THE ER, ENSURE THAT THE LAYOUT?
AVOID CABLE CONGESTION PROVIDE ADEQUATE STORAGE OF CABLE SLACK
120
THE ONU IS ASSUMED TO BE MOUNTED ON THE _________?
OUTSIDE OF THE RESIDENCE
121
(RCDD QUESTION) CALCULATE TR ?
205 SQFT
122
TR SPACE REQUIRED WORK AREA ?
1 WORK AREA= .75 SQFT
123
ER SPACE REQUIRED BAS DEVICES?
1 BAS DEVICES = .25 SQFT
124
WHEN LAYING OUT CABLE PATHWAYS TO THE ER , ENSURE THAT THE LAYOUT IS____________?
AVOID CABLE CONGESTION PROVIDE ADEQUATE STORAGE OF CABLE SLACK
125
THE ONU IS ASSUMED TO BE MOUNTED ON THE __________?
OUTSIDE OF THE RESIDENCE
126
THE OPTICAL NETWORK TERMINAL IS RESPONSIBLE FOR MEDIA CONVERSION FROM OPTICAL FIBER TO BALANCED TWISTED PAIR NETWORK OR OTHER MEDIA IN THE HOME THIS IS ABBREVIATED AS ____________?
FIBER (ONT) TO COPPER IN THE HOME ( RESIDENTIAL)
127
THE BACKBONE DISTRIBUTION SYSTEM SHALL HAVE NO MORE THEN ?
2 LEVELS OF CROSS CONNECTIONS
128
WHAT IS A THREADED METAL RACEWAY OR CIRCULAR CROSS SECTION WITH A COUPLING ?
RMC ( RIGID METAL CONDUIT )
129
WHAT PATHWAY TYPE IS COMMONLY CALLED THIN WALL ? ALSO THE LIGHTEST WEIGHT METALLIC CONDUIT MANUFACTURED?
EMT CONDUIT
130
WHAT TYPE OF COUPLING OR CONNECTORS ARE USED TO INSTALL EMT?
SET SCREWS COMPRESSION TYPE
131
( RCDD QUESTION ) LONG QUESTION ABOUT A 6 STORY BUILDING AND HOW MANY CONDUITS WOULD BE REQUIRED TO CONNECT TR ROOMS ?
( 36 ) 4” CONDUITS
132
MINIMUM CONDUIT REQUIREMENT FOR THE FIRST FLOOR
(4) 4” CONDUITS
133
CABLE THAT IS IMPROPERLY SUPPORTED CAN CAUSE WHAT ______?
SLIPPAGE AND STRETCHING
134
SLOTS ARE INSTALLED
6-24 “ FLUSHED TO A WALL
135
SLOT AREA ?
60 SQUARE INCH SERVING UP TO 40000 SQFT
136
SLOT SERVING ABOVE 40000 SQFT SHOULD INCREASE
12 SQUARE INCHES ( 60+12= 72 SQ IN )
137
IF THERE IS A 20 STORY BUILDING WHERE SHOULD THE ER BE LOCATED ?
IN THE MIDDLE OF THE BUILDING ( 10TH FLOOR )
138
WHAT MICE CATEGORY COVERS HEAVY INDUSTRIAL ?
MICE 3
139
RECOMMENDED MINMUM CABLE TRAY HEIGHT WITH IN A DATA CENTER ?
9 FT
140
WHAT DOES N MEAN ? WHAT DOES N + 1 MEAN ?
NEED NEED PLUS (1) ADDITIONAL
141
WHAT LOCK TYPE HAS THE OUTSIDE LEVER ACCESSED BY KEY WHEN TY W DOOR IS LOCKED AND INSIDE LEVER IS ALWAYS FREE OF EGRESS ?
CLASSROOM LOCK
142
WHAT CAMERA TECHNOLOGY USES A MOTOR TO DRIVE THE FOCAL LENGTH ?
ZOOM LENS
143
CAMERA MINIMUM MOUNTING HEIGHT ( INTERIOR) ?
ZOOMS LENS
144
CAMERA MINIMUM MOUNTING HEIGHT ( EXTERIOR) ?
EXTERIOR 15 FEET
145
AN AUTHORITY HAVING JURISDICTION ( AHJ) WILL TYPICALLY REQUIRE A PULL STATION WITHIN HOW MANY FEET FROM A DOOR ?
WITH IN 5 FEET
146
AN AUTHORITY HAVING JURISDICTION ( AHJ ) WILL TYPICALLY REQUIRE A PULL STATION WITHIN HOW MANY FEET FROM A DOOR ?
WITHIN 5 FEET
147
PLACE PULL STATIONS SO THEY ARE NEVER MORE THAN HOW MUCH FROM EACH OTHER ?
MAX 200 FEET APART FROM EACH OTHER
148
PLACE HOW FAR SHOULD THE PULL STATION BE ABOVE THE FINISHED FLOOR ?
48-54” AFF
149
WHAT ARE RANDOMES ?
ANTENNA COVERS
150
151
Y
152
153
154
155
WHAT IS THE PATH LOSS OF A RANDOME COVER ?
5DB SIGNAL LOSS
156
FIVE TYPES
157
158
159
160
WHAT IS THE PATH LOSS OF A RANDOME COVER?
5DB SIGNAL LOSS
161
5 TYPES OF CABLING IS ALLOWED IN A DAS CABLING INSTALLATION INFRASTRUCTURE WHAT CABLE IS NOT ALLOWED?
62.5 MICRON IS NOT ALLOWED IN A DAS CABLING INSTALLATION
162
WHAT CABLE TYPE IN A DAS SYSTEM CAN ALSO BE USED FOR POWERING THE ANTENNAS
HYBRID FIBER ( CONTAIN BOTH FIBER AND POWER)
163
ON THE OUTSIDE WALL OF A BUILDING , WHAT ANTENNA SHOULD BE CONSIDERED FOR AESTHETICS?
FLAT PANEL OUTDOOR TYPE
164
TRADITIONAL BAS DEVICES USE WHAT CABLE?
16/22 COPPER GAUGE CABLE
165
MECHANICAL ROOM TOTAL BAS DEVICES
5 FOR EVERY 54 SQFT
166
THE ACTION OF MOLECULES PRESSING CLOSER TOGETHER IS CALLED _________?
RAREFACTION
167
168
HOW MANY LAYERS IS THE OSI MODEL
7 LAYERS
169
WHAT IS THE HOOK USED TO REMEMBER ________?
All PEOPLE SEEM TO NEED DOMINOS PIZZA 7 DOWN TO 1
170
NAME ALL OSI MODELS LAYERS ?
APPLICATION PRESENTATION SESSION TRANSPORT NETWORK DATA SIGNAL PHYSICAL
171
WHAT LAYER IS NETWORK ?
NETWORK (3)
172
WHAT LAYER IS THE FILE TRANSFER ?
APPLICATION (7)
173
WHAT LAYER IS BILLING ?
TRANSPORT (4)
174
WHAT LAYER IS NIC CARD ?
PHYSICAL (1)
175
WHAT IS THE CONVERGENCE OF VOICE OVER IP TECHNOLOGY WITH SOFTWARE CAPABILITIES?
UNIFIED COMMUNICATION ( VOIP WITH SOFTWARE )
176
POINT TO POINT BIDIRECTIONAL VIDEO COMMUNICATIONS INCLUDE _________?
VIDEO CONFERENCING
177
WHAT IS THE MOST DEMANDING OF ALL NETWORK APPLICATIONS FROM A RESOURCE PROSPECTIVE?
VIDEO CONFERENCING
178
FUNCTION DESIGN IS REFERRED TO AS _________?
TOP-DOWN DESIGN
179
PHYSICAL DESIGN IS REFERRED TO AS ____________?
BOTTOM-UP DESIGN
180
WHAT DEVICE PROVIDES AN EXTENDED LAYER OF PERFORMANCE EVALUATION TO ENSURE THERE ARE NO ANOMALIES ?
AN OTDR
181
IN CONTIGUOUS OPERATION ENVIRONMENT, THERE ARE CRITICAL FACTORS TO CONSIDER
FAMILIARITY WITH THE ROUTES AND SPACES CABLE COMPOSITION (TYPE)
182
WHAT IS THE ADVANTAGE AND DISADVANTAGE OF AN AERIAL PATHWAY ?
INSTALLS QUICKLY BUT LOOKS UGLY
183
ENTRANCE FACILITY UNDERGROUND REQUIRE __________?
(4) 4” CONDUITS PLUS A SPARE 4” (TOTAL-=5)
184
WHAT IS A EASEMENT?
RIGHT OF WAY ( WRITTEN PERMISSION TO INSTALL YOUR OSP ON SOMEONE ELSES PROPERTY)
185
MUNICIPALITIES MAY REQUIRE PERMIT WHICH ARE ?
DISTANCE BASED FEE ( TOTAL LENGTH OF THE OSP CABLE)
186
( RCDD QUESTION) YOU HAVE 2 BUILDINGS SEPARATED BY A FIELD ABOUT 599 FT APART. HOW MUCH CABLES SHOULD THE DESIGNER DESIGN FOR IN THIS SCENARIO
699FEET ( ADD AN ADDITIONAL 50FT ON EACH END ALLOW FOR TERMINATION OR CONVERSION
187
NO MATTER WHERE A CONDUIT ENTERS A ROOM, THE CONDUIT MUST ENTER THE ROOM.
MINIMUM 4” ABOVE THE FLOOR OR DOWN FINISHED CEILING
188
COMMON GROUND ALLIANCE HAS ADOPTED THE COLOR
ORANGE FOR TELECOMMUNICATION AND CATV
189
WHAT IS THE MINIMUM DEPTH OF A TRENCH?
24 INCHES FROM TOP OF CABLE TO FINAL GRADE
190
IN COLD WEATHER REGIONS , THE CABLE TRENCH SHOULD BE PLACES BELOW THE _____________?
50 YEAR FROST LINE
191
MAINTENANCE HOLE GUIDELINES
LESS THEN 12 FT=1 COVER BETWEEN 12-20FT=2 COVERS MORE THEN 20ft =3 COVERS
192
HOW MANY COVERS SHOULD THE DESIGNER CONSIDER SHE. THERE TWO MAINTENANCE HOLES BETWEEN 12-20FT AND ONE HOLE MORE THAN 20 FT ?
7COVERS
193
LOOSE TUBE FIBER AND TIGHT BUFFERED FIBER USED IN ?
LOOSE TUBE FIBER= OUTDOOR TIGHT BUFFERED FIBER = INDOORS
194
66 STYLE CONNECTING BLOCKS BECAUSE OF THEIR DESIGN FEATURES CANNOT SUPPORT __________?
CAT 6 ( BLOCK CAN ONLY SUPPORT UP TO CAT5E )
195
WHAT DO YOU CALL A CORD THAT ADAPTS FROM ST RO SC?
HYBRID PATCH CORD
196
WHAT SHOULD THE ICT DESIGNER FOCUS ON FIRST WHEN DESIGNING __________?
PATHWAY FIRST CABLING SECOND
197
HORIZONTAL CABLING IS OFTEN___________?
LESS ACCESSIBLE THE. BACKBONE CABLING
198
WHAT TRANSMISSION IS NOT ALLOWED IN HORIZONTAL CABLING SYSTEM?
62.5 MICRON MULTIMODE ( OM1 )
199
MAX LENGTH FOR COPPER CABLE SLACKS FROM TR TO WOEK AREAS ?
DO NOT EXCEED 295FEET
200
HOW MUCH CABLE SLACK SHOULD BE ALLOWED FOR FIBER IN THE TR ?
EXTRA 10 FEET
201
HOW MUCH SLACK SHOULD BE PROVIDED FOR TWISTED PAIR CABLING IN THE WORK AREA?
1 FOOT
202
HOW MUCH SLACK SHOULD BE PROVIDED FOR FIBER IN THE WORK AREA?
3.3 feet
203
IF IT IS DIFFICULT TO GET TO AN AREA IN THE FUTURE , WHAT SHOULD THE DESIGNER DO ?
INSTALL ADDITIONAL OUTLETS ( OR INSTALL2 OUTLETS
204
WHAT IS ADA A S WHAT TYPE OF LAW IS IT ?
AMERICAN WITH THE DISABILITIES ACT CIVIL LAW
205
IN THE WORK AREA , TELECOMMUNICATION OUTLET SHOULD BE LOCATED WITHIN HOW MANY FEET FROM THE AN ELECTRICAL OUTLET?
3.3 feet OF AN ELECTRICAL OUTLET
206
EACH FURNITURE CLUSTER REQUIRES AT LEAST ________?
(1) MUTOA
207
A SINGLE MUTOA SHOULD BE LIMITED TO SERVING A MAXIMUM OF HOW AMNY WORK AREA?
12 WORK AREAS
208
WHAT DO YOU CALL THE PATCH PANEL LOCATED AT THE END OF A LONG FURNITURE SECTION?
MUTOA
209
A MUTOA SHOULD BE AT LEAST HOW MANY FEET AWAY FROM THE CONNECTED HEAD END PATCH PANEL?
49 feet minimum
210
AN ITS DESIGNER SHOULD PLAN THE MOUNTING OF A MUTOA ON _________?
A FULLY ACCESSIBLE PERMANENT SURFACE LOCATION
211
EQUIPMENT CORDS ( PATCH CORDS ) SHOULD NOT EXCEED?
72 feet
212
HOW MANY WORK AREA CAN BE SERVED BY A SINGLE CONSOLIDATION POINT ?
MAXIMUM 12 WORK AREAS
213
WHEN DEALING WITH A CONSILADATION POINT , WHAT SHOULD BE CLASSIFIED AS HEAVY FURNITURE 100
100lbs or more
214
THE ITS DESIGNER SHOULD ENSURE THAT THE CONSOLIDATION POINT IS PLACE A MINIMUM OF HOW MANY FEET FROM THE TR?
49 FEET FROM TR
215
DISADVANTAGE OF A CONSOLIDATION POINT ?
MORE COMPLEX TESTING
216
NAME ONE DIFFERENCE BETWEEN A MUTOA AND A CONSOLIDATION POINT ?
MORE TESTING ON CP COMPARED TO MUTOA
217
218
WHAT IS THE POINT TO MULTI-POINT NETWORK ARCHITECTURE IN WHICH UN-POWERED OPTICAL SPLITTERS ARE USED ?
PON ( PASSIVE OPTICAL NETWORK )
219
WHY SHOULD THE DESIGNER CONSIDER A PON ?
LESS CABLING LESS SPACE LESS POWER
220
HOW MANY PORTS DOES A PASSIVE OPTICAL PON HAVE ?
2-64 FIBER PORTS
221
WHAT IS THE BIGGEST ADVANTAGES OF A PON DEVICE
PASSIVE REQUIRE NO POWER
222
HOW MANY USERS MIGHT THERE BE ON ONE PORT OF A PON ?
32 USERS PER PORT
223
HOW MANY WORK AREAS DOES A PON SUPPORT ?
2048( 64 PORTS x 32 USER PER PORT )
224
HOW SHOULD OPTICAL FIBER CABLING WITHIN A PON INSTALLATION BE TESTED ? WHAT FIBER IS USED ?
BIDIRECTIONALLY & BOTH WAVE LENGTHS SINGLE MODE ( 1310NM & 1550NM)
225
THE DESIGNER SHOULD LOCATE TELECOMMUNICATION PATHWAY AWAY FROM SOURCES OF _______? SHOULD COORDINATE WITH ___________?
EMI Owner/ STEAKHOLDERS
226
SERIOUS CONCERNS FOR EMI?
TRANSFORMERS & X-Ray EQUIPMENT
227
WHAT IS THE FILL RATIO FOR A CONDUIT THAT IS A STRAIGHT RUN ?
40% FILL
228
ALL CONDUITS SHALL BE EQUIPPED WITH A PULL CORD RATED AT __________?
Minimum 200 LBS
229
YOU HAVE (5) 4” CONDUITS WHAT SHOULD THE TOTAL AVAILABLE SPACE BE INSIDE THE PULL BOX ? ( REFER TO TABLE 5.12 )
47x60” WIDE PULL BOX ( REFER TO TABLE 5.12 )
230
AN ACCESS FLOOR PRIMARILY CONSIST OF __________?
FEET PEDESTALS STRINGERS MODULAR FLOOR PANEL STEEL FOOTING
231
AN ACCESS FLOOR DOES NOT CONSIST OF __________? ( REMEMBER THIS MORE THEN WHAT IT DOES INCLUDE )
LONGITUDINAL CROSS MEMBERS
232
REGARDLESS OF THE HEIGHT OF A FINISHED FLOOR , HOW MUCH FREE SPACE DO YOU NEED UNDERNEATH THE TILE ?
2”
233
WHAT IS THE CONCENTRATED LOAD CAPACITY FOR A RAISED FLOOR?
2000 lbs
234
J HOOKS SHOULD BE LOCATED ________ ? HOW MANY J HOOKS FOR 100 feet ?
MAXIMUM 5 ft APART QTY=20
235
WHAT ARE THE STANDARD SIZES FOR POWER UTILITY COLUMNS?
10,12& 15 FEET
236
WHAT ARE THE 6 DIFFERENT TYPES OF CABLE TRAY?
TWO SIDES RAILS VENTILATED THROUGH/BOTTOM VENTILATED CHANNELS SOLID BOTTOM SPINE BASKET TRAY/ WELDED MESH
237
WHEN THE TELECOM CABLE RUNS PARALLEL TO ELECTRICAL PATHWAYS INSIDE OF A FURNITURE, THE SEPARATION SHOULD BE A MINIMUM OF ______?
2”
238
WHAT DO YOU CALL THE PROCESS OF LIMITING FIRE AND SMOKE BY USING FIRE RESISTIVE BARRIERS TO CONTAIN IT?
COMPARTMENTATION
239
FACTORS THAT CONTRIBUTE TO THE DESIGN OF A FIRE RESISTIVE BARRIERS? ( CHOOSE TWO )
TYPE OF CONSTRUCTION OCCUPANCY LEVELS PURPOSE OF THE BUILDING EXIT ROUTES
240
NAME A TYPE OF MECHANICAL FIRE STOP SYSTEM ?
MECHANICAL CABLE TRANSIT
241
SEVERAL FIRE STOP MATERIALS ARE AVAILABLE AS PUTTY , WHY? WHAT IS IT CALLED ?
IT SWELLS UNDER HEAT INTUMESCENT
242
WHAT TYPE OF NON-MECHANICAL FIRE STOP SHOULD BE CONSIDERED TO ABSORB HEAT ?
ABLATIVE
243
WHATIS THE TELECOMMUNICATION STANDARD FOR GROUNDING AND BONDING?
ANSI/TIA 607
244
WHAT IS THE RESPONSIBILITY OF THE ICT DESIGNER?
TO PROTECT PEOPLE AND PROPERTY
245
WHAT COULD BE THE RESULT OF SUCH DISTURBANCES TO GROUNDING SND BONDING.?
DEATH OR INJURY
246
HOW OFTEN SHOULD YOU BOND THE PEDESTALS IN RAISED FLOOR ?
EVERY 4 TH PEDESTAL (LEG)
247
WHAT IS THE SIZE OF A PBB ( PRIMARY BONDING BUSBAR )
1/4x4”
248
WHERE DO YOU LOCATE THE PRIMARY BUSBAR
IN THE ENTRANCE FACILITY
249
WHERE DO YOU LOCATE THE SECONDARY BUSBAR?
IN THE ER OR TR
250
WHAT IS THE SIZE OF A SBB? ( SECONDARY BUSBAR )
1/4x2”
251
HOW DO YOU GROUND THE ET OR TR SBB?
GROUND #6 AWG TO THE NEAREST AC PANEL BOARD
252
WHAT ARE TWO ACCEPTABLE METHODS FOR PROPERLY GROUNDING AN EQUIPMENT ROOM?
AC ELECTRICAL PANEL STRUCTURAL STEEL
253
WHY SHOULD YOU GROUND THE SBB TO THE NEAREST AC PANEL?
TO EQUALIZE POTENTIAL BETWEEN THEM
254
GROUNDING AN ER, EF OR TR GROUND BAR WILL EQUALIZE THE CONDITIONS CAUSED BY_______________?
LIGHTNING ELECTROSTATIC DISCHARGE EMI CONDITIONS
255
WHAT DO YOU CALL THE BONDING CABLE BETWEEN BUSBAR TO THE AC PANEL?
TBC ( TELECOMMUNICATIONS BONDING CONDUCTOR)
256
WHAT IS A TBB? AND WHAT IS IT FOR?
TELECOMMUNICATIONS BONDING BACKBONE CABLE THAT BINDS TR’s ON DIFFERENT AREAS OR FLOORS.
257
DOWNSIDE OF A TBB HOMERUN?
TOO COSTLY TO RUN HONRUN ALL THRU THE BUILDING OR SITE
258
A BONDING CONDUCTOR SHOULD ALWAYS BE A MINIMUM OF WHAT SIZE AND LENTH ?
#6 AWG UP TO 100 feet
259
WHAT IS THE PROPOR METHOD FOR TERMINATING BONDING CONNECTIONS?
EXOTHERMIC WELD COMPRESSION CONNECTORS
260
BONDING CONNECTION SHOULD ALWAYS BE COATED WITH _________?
ANTI-CORROSION GEL
261
WHAT IS THE PROPER DEFINITION OF BONDING?
THE MATING OF TWO METALS PARTS
262
WHAT IS AN EXOTHERMIC WELD?
SEAMLESS MOLECULAR BOND
263
WHEN LIGHTNING STRIKES THE GROUND, HOW MANY FEET WITHIN THE MAIN BUILDING GROUND LOOP WILL ENERY BE COLLECTED FROM THE GROUND STRIKE?
6-20 feet
264
INTER-BUILDING OSP TELECOMMUNICATIONS CABLES ARE CONSIDERED TO HAVE LIGHTNING EXPOSURE, UNLESS ONE OF THE FOLLOWING CONDITIONS EXIST?
METROPOLITAN AREAS 140 ft OR LESS OF LENGTH OF OSP CABLING IF INSTALLING OSP AT AN ADDRESS WITH FEWER THAN 5 THUNDERSTORMS THE PREVIOUS YEAR.
265
LIGHTNING PROTECTION CODE
NFPA 780
266
WHAT IS OHMS LAW?
V= IR ( VOLTAGE = CURRENTx RESISTANCE)
267
THE ENERGY RADIATED BY A LOAD IS MAINLY RADIATED AS
HEAT
268
ONE WATT IS EQUAL TO ______?
3412 BTU
269
TWO WATT IS EQUAL TO_______ ?
6.824
270
HORSEPOWER IS A UNIT OF
MECHANICAL POWER
271
IN ELECTRICAL , AWG IS ACCEPTED WHERE ?
WORLD WIDE
272
IN AWG SMALLER NUMBER DENOTES WHAT ________?
LARGER WIRE
273
AWG SYSTEM RANGES ________?
#36 AWG UP TO #4/0
274
CIRCULAR MILS RANGES ?
#4 /0 AND ABOVE
275
THREE STRANGE FLUCTUATION THAT HAPPEN TO CURRENT?
A SWELL ( INCREASE IN POWER ) A SAG ( DECREASE IN POWER ) AN INTERRUPTION ( TOTAL ABSENCE OF POWER )
276
HOW DO YOU IDENTIFY ISOLATED GROUND?
ORANGE TRIANGLE OR ORANGE RECEPTACLE
277
WHAT K RATING WOULD YOU USE FOR A DATA CENTER ?
K20 TRANSFORMER
278
WHAT TO AVOID WHEN TERMINATING POWER?
AVOID TERMINATING ALUMINUM TO COPPER
279
DIFFERENCE BETWEEN A RPP AND PDU
THEY ARE THE SAME BUT PDU CONTAINS POWER TRANSFORMER AND RPP DOES NOT
280
WHERE DO YOU INSTALL AN RPP?
END OF ROW
281
WHAT DEVICE OR PROCEDURE PROTECTS A CIRCUIT FROM ACCIDENTAL RENERGIZATION ?
LOCKOUT/ TAGOUT ( LOTO )
282
WHAT IS THE FINAL STEP/PROCEDURE FOR THE LOTO PROCEDURE?
TAG BOTH LOCALLY AND REMOTELY INDICATING THE EQUIPMENT IS DE-ENERGIZED
283
WHAT BATTERY TERMINATION CONNECTOR TYPE SHOULD YOU SEE?
COMPRESSION TYPE
284
WHICH SHOULD YOU TRY TO AVOID ?
MECHANICAL CONNECTORS
285
HOW MANY AIR CHANGES FOR A BATTERY ROOM ?
4 AIR CHANGES PER HOUR
286
HOW MANY AIR CHANGES FOR A TUNNEL?
3 AIR CHANGES PER HOUR
287
HOW MANY AIR CHANGES FOR A TR ROOMS ?
1 AIR CHANGES PER HOUR
288
WHAT IS THE OPTIMAL TEMPERATURE FOR THE STORAGE OF BATTERIES
77 DEGREES
289
HOW MANY CLASSES OF TELECOMMUNICATIONS ADMINISTRATION ARE THERE? WHAT ARE THEY ?
4 CLASSES *PREMISES SERVED BY A SINGLE ER *SINGLE BUILDING OR A TENANT SERVED BY ONE OR MORE TELECOMMUNICATION SPACES *CAMPUS *MULTISITE SYSTEM
290
WHIS
291
WHICH CLASS ADMINISTRATION IS THE FOLLOWING SERVED BY A SINGLE ER ?
CLASS 1
292
WHICH CLASS ADMINISTRATION IS THE FOLLOWING THAT INCLUDES OSP ?
CLASS 3
293
THE ANSI/TIA STANDARD FOR ADMINISTRATION?
TIA -606
294
CONNECTING HARDWARE IDENTIFICATION COLOR CODE DEMARC NETWORK CONNECTION COMMON EQUIPMENT FIRST LEVEL BACK BONE, SECOND LEVEL BACKBONE , HORIZONTAL CABLING OSP OR CAMPUS BACKBONE.
ORANGE GREEN PURPLE WHITE GRAY BLUE BROWN
295
WHAT ARE THE PERFORMANCE METRIC/STANDARDS USED TO BENCHMARK THE PERFORMANCE?
VISUAL INSPECTION RUB-OUT TEST ,SCRAPE TEST AND ADHESION TEST
296
WHAT IS THE TEST STANDARDS FOR LABELS?
UL969 MARKING AND LABELING SYSTEMS
297
LABELLING ON CABLE SHOULD BE AFFIXED WHERE ?
AT BOTH ENDS OF EACH PATHWAY
298
AN INCREASING NUMBER OF ICT PROJECTS ARE DRIVEN BY WHAT METHOD OF SUSTAINABLE BUSINESS PERFORMANCE?
SIX SIGMA
299
IN ORDER FOR THE ICT PROFESSION TO IDENTIFY THE BEST SOLUTIONS FOR THE CLIENT NEEDS THEY MAY HAVE TO PROVIDE? ( CHOOSE TWO )
PRELIMINARY BUDGET BUMBER TIME CONSTRAINTS AND OR MILESTONES
300
A GOOD TELECOMMUNICATION PROJECT MANAGER WAS ?
THE ABILITY TO COORDINATE WITH DIVERSE GROUPS OF PEOPLE
301
THE DESIGNER ON A LARGE PROJECT COULD SERVE AS WHAT ?
PROJECT MANAGER
302
INSTALLATION ISSUES REQUIRE COORDINATION WITH WHOM?
JOBSITE SUPERVISORS
303
A TELECOMMUNICATION PROJECT MANAGER PERFORMS PROCUREMENT OF WHAT TWO TYPES ?
BULK PURCHASES AND JUST-IN-TIME PROCUREMENTS.
304
ICT DESIGNER MAY BE REQUIRED TO ?
REVIEW PURCHASE ORDERS
305
AT A MINIMUM THE SCOPE WORK DOCUMENTS MUST COVER? ( CHOOSE TWO )
BULK PURCHASES AND JUST-IN-TIME PROCUREMENT
306
THE FOLLOWING SHOULD BE CONSIDERED INCLUSION IN A COMPREHENSIVE WORKING OUTLINE ?
THE CONTEXT OF THE PROJECT AND TECHNICAL CONSIDERATIONS
307
IF THE DESIGNER IS ASKED TO RETROFIT AND EXISTING BUILDING WHAT SHOULD THEY DO?
REVIEW ANY EXISTING DOCUMENTATION
308
DOCUMENTING THE LIFE CYCLE OF A PROJECT IS PROVIDED BY WHO AND HOW ?
BY THE CONTRACTOR VIA WORK BREAKDOWN STRUCTURE ( WBS )
309
WHAT IS A WBS AND WHAT DOES IT DO ?
WORK BREAKDOWN STRUCTURE DOCUMENTS PROJECT LIFE CYCLE
310
WHAT TWO SCHEDULING METHODS USE DIAGRAMS
PERT AND CPM ( CRITICAL PATH METHOD )
311
CABLE PLACEMENT IS GOING TO BE COMPLETED IN WHAT WEEK AND MONTH ?
JUNE WEEK 6
312
WHAT IS A ANALOGOUS ESTIMATE?
TIME/COST ESTIMATE FROM A SIMILAR PROJECT IN THE PAST
313
YOU HAVE A PROJECT IN CHICAGO AND NOW YOU ARE DOING A SIMILAR PROJECT IN NEW YORK WHAT ESTIMATING METHOD SHOULD THE DESIGNER USE?
USE PAST INFORMATION WITH CAUTION
314
A CUSTOM CLOSEOUT PLAN SHALL BE DEVELOPED AND MANAGED BY WHO ?
THE DESIGNER
315
WHAT SHOULD THE CLOSE OUT PLAN INCLUDE?
SPARE PARTS & TRAINING RECORDS
316
WHO HIRES THE ARCHITECT?
THE OWNER
317
WHO ON THE DESIGN TEAM IS A LICENSED PROFESSIONAL BY THE STATE OR LOCAL AUTHORITY?
THE ENGINEER
318
DESIGN PREPARED FOR THE OWNER WITH GENERAL DESIGN CRITERIA AND PRELIMINARY ESTIMATING IS A __________?
SCHEMATIC DESIGN
319
WHAT DESIGN PHASE IS EARLY CONFLICTS RESOLVED ?
EARLY DESIGN DEVELOPMENT
320
ICT DESIGNER SHOULD EVALUATE ?
STANDARDS AND CODES
321
IF THE DESIGNER REPORTS THE FINDING AND RECOMMENDATIONS TO THE STAKEHOLDERS IN BIDDING AND NEGOTIATION , STEPS TAKEN DURING THIS PHASE CAN INCLUDE WHAT ?
RESPONSE EVALUATION
322
DURING THE BID PROCESS WHAT IS THE DESIGN TEAM DOING ?
EVALUATING , NEGOTIATING, CONSIDERING ALTERNATIVES
323
WHAT IS THE DIFFERENCE BETWEEN AND RFQ AND RFP?
RFP PROVIDES MORE DETAIL WITH MATERIALS, EQUIPMENT AND COMPONENTS
324
ONCE BIDS ARE RECEIVED FROM THE CONTRACTOR , THE OWNER AND DESIGN TEAM WILL REVIEW THE BID TO ____________?
AWARD CONTRACT
325
THE TWO TYPES OF BID AWARDED ARE _____________?
LOW BID AND NEGOTIATED BID
326
THE ICT DESIGNER RESPONSIBILITY IS COMPLIANCE WITH __________?
THE CONTRACT DOCUMENTS
327
THE DESIGN TEAM MAY COORDINATE WITH STAKE HOLDERS TO
RESOLVED CONFLICTS
328
WHAT TYPE CONTRACTS IS A STIPULATED SUM
FIXED PRICE CONTRACT
329
WHAT IS A COST PLUS FEE CONTRACT ?
REIMBURSED PLUS A FEE
330
WHAT IS USED TO FACILITATE MINOR FIELD CHANGES ?
FIELD ORDER
331
WHAT IS FORMAL DOCUMENT THAT DEFINES REQUIRED CHANGES IN PROJECT SCOPE AND IDENTIFIES ASSOCIATED CHANGES TO THE TIME FRAME AND DOLLAR AMOUNT ?
CHANGE ORDERS
332
WHAT INFORMATION DOES RH CONTRACTOR SUBMIT TO RHE DESIGN TEAM FOR APPROVAL?
SUBMITTAL
333
WHAT DO YOU DO IF A MATERIAL FOR A PROJECT IS NOT AVAILABLE?
RESUBMIT A NEW SUBMITTAL EITH ALTERNATIVE MATERIALS THAT MEETS THE ORIGINAL SPECS
334
IN THE EVENT THE SUBMITTAL IS REJECTED , THE DESIGNER MAY NEED TO ______________? (CHOOSE TWO )
REVIEW CONTRACT DOCUMENT AND REQUEST VARIANCE
335
SOME OF THE ITEMS CONTRACTOR WILL NEED TO SUBMIT TO THE GC ?? ( CHOOSE TWO )
SHOP DRAWINGS AND TEST RESULTS
336
WHO IS RESPONSIBLE FOR FINALIZING MOVE-IN AND FIRST USE ACTIVITIES?
ARCHITECT AND CONSTRUCTION MANAGER
337
TELECOMMUNICATION DESIGN SHOULD INCLUDE 3 ELEMENTS? ( ALL THE ABOVE )
SPECIFICATIONS DRAWINGS SOFT ESTIMATE
338
WHAT DOCUMENT SHOULD BE PREPARED LISTING EACH TASK WITH A COST PLACED BESIDE THEM ?
SCHEDULE
339
WHEN PREPARING PROJECT ESTIMATE THE ICT DESIGNER SHOULD INCLUDE IN THE COST ?
FEES FOR INSPECTION AND PERMITS
340
THE ICT DESIGNER ROLE IN COORDINATION MEETINGS CAN INCLUDE? ( CHOOSE TWO )
DISCUSSING DESIGN CONCERNS ASSISTING IN THE RESOLUTION OF UNFORESEEN CONDITIONS , CHANGE ORDERS, RFI AND CHANGES TO PROJECT CRITICAL PATH
341
342
THE GENERAL CONTRACTOR PROJECT SUPERINTENDENT IS CRITICAL FOR ??
SYNCHRONIZING THE DAILY ACTIVITIES OF ALL TRADES THROUGH DAILY OR WEEKLY MEETINGS
343
WHO HAS FINAL DECISION RESOLVING DISPUTES WITH CONTRACTOR OR SUPPLIERS
THE GENERAL CONTRACTOR
344
IF SPECIFIC QUESTION ARISE
SUMBIT AN RFI
345
PROJECT KICK OFF MEETING SHOULD GO OVER
PROJECT SCHEDULE/COMPLETION DATE RFI PROCESS
346
WHAT IS ONE OF THE CRITICAL DECISION THAT WILL COME OUT OF THE PRIME AND SUBCONTRACTOR COORDINATION MEETING
CLOSEOUT PROCEDURES
347
348
PROGRESS MEETING WILL BE CONDUCTED WITH THE CLIENT AND THE CONTRACTOR EVERY ________?
WEEK
349
WHAT IS AN IMPORTANT TOPIC IN WEEKLY PROGRESS MEETINGS ?
REVIEW ALL OPEN RFI’s
350
PROJECT CLOSEOUT CONSIST OF _______? ( CHOOSE TWO )
PUNCH LIST TIMELINE AND COMMUNICATE ANOMALIES TO RESPONSIBLE PARTY
351
WHAT IS HC?
HORIZONTAL CROSS-CONNECT (FLOOR DISTRIBUTION)
352
WHAT IS IC ?
INTERMEDIATE CROSS-CONNECT ( BUILDING DISTRIBUTION)
353
WHAT IS MC ?
MAIN CROSS-CONNECT ( CAMPUS DISTRIBUTION)
354
CALCULATE ELECTRICAL UTILITY BILL ( RCDD QUESTION )
$99
355
THE TBC SHOULD ALWAYS BE AS SHORT AS POSSIBLE TO LONGER THAN ______?
30 feet ( 9 M)
356
WHAT IS THE SIMPLIFIED ZONE OF PROTECTION?
RADIUS EQUAL TO TWICE THE HEIGHT OF THE MAST GIVES A CONE OF SHIELDING WHICH AN OBJECT WILL BE STRUCK OCCASIONALLY.
357
IF THE USEABLE FLOOR EXCEED 10000 FEET THE ICT DESIGNER SHOULD ________?
CONSIDER ADDITIONAL TR
358
WHAT IS A GROUND LOOP ?
TWO PARALLEL THAT HAVE IDENTICAL CONDUCTIVE TERMINATION TO TWO SEPARATE GROUNDING
359
HOW MANY ADDITIONAL CONDUITS SHOULD THE DESIGNER ADD TO THE FLOOR ?
ADDITIONAL 4” IF FLOOR EXCEEDS 40000SQFT
360
LIGHTNING HEIGHT IN TR ROOMS ?
8.5 FEET
361
WHAT TR ROOM TYPE/EQUIPMENT WILL BE USED IN THE FOLLOWING SMALLER ROOM IN A 5000 SQFT?
SHALLOW ROOM TYPE
362
WHAT TR ROOM TYPE/EQUIPMENT WILL BE USED IN THE FOLLOWING SMALLER ROOM IN A 1000 SQFT?
CLOSET WITH A WALL CABINET
363
MOISTURE CONTENT OF PLYWOOD AND WHY ??
MAXIMUM 15% TO REDUCE WARPING
364
WHAT ARE THREE FUNDAMENTAL CABLE TOPOLOGIES ?
STAR / RING / BUS
365
WHAT IS A HYBRID DEVELOPED?
HIERARCHICAL STAR STAR-WIRED RING CLUSTER STAR TREE MESH
366
WHAT DOES THE ONT DO ?
CONVERTS FIBER TO TWISTED PAIR COPPER IN HOMES
367
WHAT IS THE FIRST PAIR ON T568B? ( THIS IS A RCDD IMAGE QUESTION)
PAIR 2
368
WHAT IS THE COLOR FOR PIN 6 off of T568B? ( THIS IS A RCDD IMAGE QUESTION)
GREEN
369
WHAT CAN BE USED IN MUTOA IN SOME CASES?
HIGH DENSITY PATCH PANELS