The backpack is designed to transfer ___% of the load to hips
60
The backpack harness and cylinder weight approximately ____ lbs.
30.25
The air cylinder has a maximum working pressure of _____ psi
4,500
When full, the 45 min air cylinder contains ____ cubic feet of air
65.6
When full, the 60 min air cylinder contains ____ cubic feet of air
87
The air cylinders time rating is classified at a user rate of ___ liters per minute.
40 liters
The air cylinder is hydrostatically tested every ___ years
5
The department designator for newer bottles is “LFD” imprinted on the ___ inch luminescent band.
2”
The first stage regulator lowers cylinder air pressure to a nominal ___ psi
115
The relief valve on the first stage regulator activates to protect the system when the regulator pressure exceeds ___ to ___ psi.
200-225
The low pressure SCBA audible alarm activates at ____ to ____ psi.
1035-1215 psi
Once the low pressure SCBA audible alarm activates, the audible alarm will continue to sound until the air pressure drops below ___ psi
200
When the pressure drops below 50% of cylinder capacity, the HUD LED representing 1/2 cylinder capacity starts to flash, and continues to flash for a short time (approximately __ seconds) before returning to continuously lit.
20 sec
When pressure drops to 25%, the 1/4 LED on the HUD will turn ___ and begin to flash between ____ and ____ psi.
2. 1035-1215
When the pressure drops to ___% of cylinder capacity, the red 1/4 HUD LED begins to flash noticeably faster and continues flashing in this manner until air pressure drops below approximately ___ psi,at which time the display will turn off
2. 200 psi
There are how many battery status indicators amber LEDs on the SCBA?
3
HUD
Backpack harness
PASS device
The amber LED on the Backpack and PASS device will flash once every ___ seconds to indicate a usable battery condition
10
The amber LED on the Backpack and PASS device flashes every ___ seconds to indicate a low battery condition
2
Turning the bypass knob on the second stage regulator clockwise or counterclockwise will provide a constant air flow?
Counterclockwise
On the PASS, depress the red “ALARM” button for __ to __ sec to put into full alert.
1 to 2
Lack of movement for ___ seconds will activate the staged alarm with LED lights alternating what colors?
2. Green and red
After 20 seconds of no movement the “staged” PASS alarm begins. Volume then increases every __ seconds of inactivity with full alarm being reached at ___ to ___ seconds.
2. 30-45 sec
The buddy breather system consists of ___ inch intermediate pressure hose with a “Y” block
39”
For the VAS button, one depression yields push to talk feature or depressing the button ___ times will yield hands free continuous use. Depressing the button ___ additional times will turn unit off.
2 and 2