What PAES number is slaughter house?
PAES 411
Slaughterhouse with required facilities and operational procedures to serve any market
“AAA” slaughterhouse
The site shall be elevated to at least ______ above the adjacent ground.
The fill material shall be compacted thoroughly by rolling or pounding.
600 mm
Ceilings shall be at least ______ from the floor.
3 m
Window sills shall be sloped at _____.
45°
Sticking and bleeding area, minimum distance from the carcass suspension
contact point to the floor
Animals Distance (m)
Cattle 3.7
Calves 2.7
Sheep & Goat 2.4
Swine 2.6
A room shall be provided for supplying hot water with temperature of_______.
It should be equipped with heating facilities.
80°c
Volume of concrete per CHB
4×8×16 - 0.001 m³
6×8×16 - 0.003 m³
8×8×16 - 0.004 m³
Minimum pipeline pressure for water supply
system in slaughterhouse
20 psi
Minimum width of the doorways for
slaughterhouse
1.5 m
Number of drain inlets provided in the
slaughterhouse for 40 m2 space
1 inlet