What are the engine starter cranking limits
1st and 2nd attempt
90 sec ON – 10 sec. OFF
3rd thru 5th attempt
90 sec ON – 5 min. OFF
What are the Dry Motoring limits
1st attempt: 90 sec. ON – 5 min. OFF
2nd thru 5th attempt: 30 sec. ON – 5 min. OFF
What are the APU Starter limits
No more than three start attempts in one hour, 2 minute delay required between start attempts