Flow Path?
FIRE ALWAYS MOVE FROM HIGH TO LOW PRESSURE
movement of heat and smoke from the HIGHER PRESSURE within the fire area towards the LOWER pressure areas accessible via doors, window openings and roof structures….may be several flow paths within a
structure
-this can be BIDIRECTIONAL OR UNIDIRECTIONAL depending on LOCATION of MAIN BODY OF FIRE IN RELATION TO VENTILATION OPENING AND NEUTRAL PLANE
Modern Content Fire?
fires that involve HYDROCARBON AND SYNTHETIC based contents such as foam rubber, nylon , rayon and polypropylene…HIGH HEAT RELEAS RATE
When Ventilation is controlled and communicated by LCO INSIDE FIRE AREA TO BE VENTED…
dramatically increase survivability of trapped civilians and increases the safety of our members and improves overall operation
Moder Content Fires…
Traditional Fire..?
Incipient
growth
fully developed
decay
Moder Content fires?
COORDINATED ATTACK FIRE BEHAVIOR CURVE:
Factors affecting ventilation tactics…
Until________it is critical to control flow path of fire?
CHARGED HOSE LINE
Ventilation profile?
appearance of the fire buildings ventilation points showing the flow paths of heat and smoke out of the structure as well as air movement into the structure , this is an EVALUATION OF FIRE BEHAVIOR
examples of ventilation profile indicators :
** changes of ventilation profile indicators must be communicated via HT to LADDER COMPANY OFFICER operating inside fire area and INCIDENT COMMANDER
While in decay stage, fire may no longer have enough pressure to push smoke from the fire area or building, assumption that the absence of smoke pushing from a building is a positive sign, is NOT ACCURATE
MODERN CONTENT FIRES require control of ventilation tactics to prevent a ventilation induced flashover
modern content-develop faster-high heat-more venting flames fill a window..MORE SEVER CONDITIONS
All HORIZONTAL Ventilation tactics- whether venting for extinguishment or ventilation for search, require communication and coordination with LCO…
INSIDE FIRE AREA TO BE VENTED
Horizontal ventilation tactics include controlling door and window openings until
CHARGED HOSELINE IS ADVANCING WITHIN THE FIRE AREA and extinguishing the fire
If officer encounters HIGH HEAT/SMOKE CONDITIONS WITHOUT A charged hose line …
he CAN direct members to IMMEDIATELY EXIT(not a must) or ISOLATE AREa, limit additional .ventilation— horizontal vent prior to extinguishment WILL NOT cool or relieve these conditions, but will allow fire to grow
CHARGED LINE IS NEEDED
FLOOR ABOVE:
if the LADDER company officer determines the fire has NOT communicated to the floor above, LIMITED ventilation is justifiable if if facilitates search operations,
-so officer can ventilate to facilitate search if fire has NOT COMMUNICATED to floor above
Initial Vertical Ventilation must be controlled, communicated and coordinated by LCO operating inside the fire area to be vented
LCO should establish door control of fire area and perform a vent profile at the entry point (pay attention to AIR being pulled in)
-COMMUNICATE WITH ROOF when vertical vent is NOT to be taken , or delayed (unable to gain door control and/or uncontrolled fire in the public hall or stairwell)
Roof FF can perform INITIAL VERTICAL VENTILATION upon reaching the roof.
LCO will advise roof when vertical vent should be withheld or delayed
IF INITIAL VERTICAL VENT is withheld, ROOF FF CAN FORCE BULKHEAD DOOR AND PROBE FOR VICTIMS, THEN CONTROL
MEMBER on Exterior waiting to perform the Horizontal Ventilation for Extinguishment OF IMMEDIATE FIRE AREA shall listen for these transmission?
member must PREPARE to vent for extinguishment
member must get PERMISSION
Fire progresses past the INCIPIENT STAGE, fire is IDLH…NO MEMBER SHALL ENTER, LEAVE,OPERATE in an IDLH UNLESS MEMBER TEAMS UP WITH AT LEAST ONE OTHER MEMBER AND …
remains within VISUAL OR VOICE CONTACT with that member…each member of search team shall know the company identity and assigned position of other members…HT does NOT replace Visual/Voice contact….AT LEAST ONE of the members must be able to contact a HT equipped member of the safety team outside the IDLH ATMOSPHERE
Only exception….KNOWN LIFE HAZARD
Still must notify LADDER COMPANY OFFICER AND RECEIVE APPROVAL
LCO may disapprove rescue and may have quicker access from interior
Prior to Venting the window, for search, member must…?
auto exposure..
extension of fire via the exterior of a building from a fire originating in the SAME BUILDING
decay stage..
–stage of fire development within a structure characterized by either a DECREASE in the fuel load OR AVAILABLE OXYGEN (ventilation limited)
Flashover..
feedback from fire gases in EXCESS of 1100 degrees reach auto ignition temp more or less simultaneously
BI directional flow path..
flow path where gases from fire area (high pressure) flow TOWARDS ventilation point (LOW pressure) and an entrainment of fresh air in the opposite direction back to the seat of the fire.
NEUTRAL PANE
boundary layer in a structure fire where below it, air will be drawn into the structure, and above it, combustion gases will be exhausted …can be indication of stage of fire and WILL DROP down to floor as fire grows in intensity