An APU fire will (annunciator) …………………. and ……..the APU
illuminate the fire light and
shutdown the APU and discharge the fire bottle
The aircraft Master Warning annunciators will
not illuminate if
if the APU FIRE light illuminates
The APU FAIL light will illuminate if …………………………………. and
………………the start
the APU fire extinguisher bottle pressure is low
inhibits
If the fire switch is not manually activated after
an eight second delay…what happens ?
The APU FIRE switchlight may be manually depressed
to activate the …….
the APU fire extinguisher
An APU start attempt in flight…………..after a dual generator failure.
is prohibited
The APU generator amperage limits on the
ground and inflight are:
200 ground
230 flight
The maximum altitude for APU operation
is…..
FL300
In-flight APU starts are limited to…………(altitude)
FL 200 and below