Pitot static system malfunction general checklist flow
EED Internal Failure general checklist flow
If EED modes do not switch
If EED still failed
If EED still failed (you can view EED data on the MFD)
Which instruments display zero with no sensor data?
RPM and EGT
General checklist flow for EED sensor failure
If EED is in Slave
If OFF condition persists
If OFF condition continues
When the EED detects an internal failure that does not affect an ability to display engine data, ____ is displayed in the center of the EED
BIT FAIL
General checklist flow for EED Internal BIT Failure
If failed EED is Master
General checklist flow for EED hot
If EED HOT is displayed in the EED message window, what happens if you are in the day mode?
Brightness is reduced by 50%
If EED HOT condition persists for 1 minute, what will happen?
The EED lamp shuts off
How can you confirm EGI Failure - GPS?
Check for .8nm/hour accuracy (drift rate) on the EGI page
If a GPS failure occurs, should you cycle EGI power to regain GPS functionality
NO. INS is still availble provided EGI power is not cycled. Cycling the EGI power switch while in flight will force an air alignment which cannot be accomplished without GPS, forcing the EGI into ATT mode. The EGI supplies only attitude and relative heading data in ATT mode and g is not available
General checklist flow for EGI Failure - GPS
Confirm EGI solution at UR-3 on UFCP EGI Page - EGI
Some indications of EGI Failure - INS include…
Attitude removed from HUD and MFD displays
Empty circle replaces EADI on MFD
Heading info on the HUD represents GPS derived ground track
General checklist flow for EGI Failure - INS
If inflight alignment fails
Some indications of EGI Failure - TOTAL include…
Attitude information removed from HUD and MFD
Empty circle replaces the EADI
360 will be displayed on the heading scale on the MFD and be blank on the HUD
With a HUD only failure, what should you check?
Check RCP circuit breaker panel (right console) status to verify HUD CBs are in
What is a consideration for UFCP only failure
Set AAP - Both to enable your backup controls
AC power transients (generator reset or successful generator crossover after gen failure) may cause HUD blanking for how long?
3-5 seconds
General checklist flow for HUD and/or UFCP failure
If it’s still failed
What are 12 indications of MDP failure?
What is the general checklist flow for MFD Failure?
If MFD is still failed
What is the general checklist flow for MDP degraded?
What is the general checklist flow for MDP failure?
Note: If MDP fails check center pedestal circuit breaker panel for a popped MDP circuit breaker
If MDP still failed and system does not switch automatically
General checklist flow for MDP reboot