What is the purpose of the Main condenser?
How does water flow through the condenser? Start from CW pumps
What are the normal positions of the ‘B’ CD suction valves?
One of the suction valves has to be full open with its respective recirc valve to the correct hotwell half open
What will trip the B condensate pump?
What’s the significance of the ‘C’ reheater tray?
Condensate falls directly from the inner bottom to the hotwell. In ‘A’ and ‘B’, condensate falls on the reheater trays which then the exhaust steam from the FWPTs pass through which reheats the condensate as it falls into the hotwell. The steam that remains uncondensed then condenses on the C tube bundles
Hotwell auto makeup valve, where are they located? When would use manual or auto?
What is the normal lineup for Condensate Demins?
Why would we have demins in service?
What are the auto actions of CDN-V195?
CDN-V195 will open or close automatically to maintain <55 psid demin DP and auto open if the inlet or outlet are not full open
How to manually operate CDN-V195?
What is the drawoff valve?
Drawoff valve is downstream of demins
In pump discharge header, it removes excess condensate from hotwells. Opens based on higher level in 1C or 2C
What are the auto actions of the drawoff valve and when would you bypass it?
Auto close if MFP suction pressure too low, or high cation conductivity in the hotwell
Bypass switch is a cabinet (ZTN-C01) when you enter turbine building from catwalk on 140’ - bypass to drain to CST the bypass will only bypass the high conductivity feature, not the low FWP suction
How much flow goes through the BDHX?
The flow is determined by the temperature of the BDHX to ensure efficiency
CD downstream of the pumps is aligned to go through the BDHX to cool it and its usually around 350 gpm to keep the temperature ~135F in the BDHX
What is the BFT rated for? Temperature limits of operation?
Classify the CD Pumps
Describe CD flow through the LPFWH
CD flows through #1-#4 LPFWH increasing in temperature increasing efficiency of the plant and generator output
What is some OE on CD System?
CDN-V195 failed closed and started Three Mile Island by losing of feed so then they couldn’t feed the SG
What is the purpose of the dogbone seal?
- Prevents air leakage into the condenser while allowing movement between the turbine casings and condenser sections
What is the purpose of the water sealed Condenser Equalization Duct and where is it located?
How is each section of the condenser protected from overpressure?
Rupture discs set at 5 psig on its associated LP turbine hood
Why do the tube lengths vary in the three condensers?
To compensate in part for the progressively higher CW temperatures since it flows through them in series
What is the purpose of the Condenser Waterboxes?
Provide the supply and return headers to the condenser tubes
How can Reheater Tray level affect ‘A’ AFP operability after a LOOP?
After an MSIS, level can back up and potentially back up the steam line drains and cause the pump to be inoperable